A platform for research: civil engineering, architecture and urbanism
ANSI/ASHRAE/INESNA Standard 90.1-2007 Final Determination Quantitative Analysis
The United States (U.S.) Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2004. The final analysis considered each of the 44 addenda to ANSI/ASHRAE/IESNA Standard 90.1-2004 that were included in ANSI/ASHRAE/IESNA Standard 90.1-2007. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from Standard 90.1-2004 were reviewed by DOE, and their combined impact on a suite of 15 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOEs final determination. However, out of the 44 addenda, 9 were preliminarily determined to have measureable and quantifiable impact.
ANSI/ASHRAE/INESNA Standard 90.1-2007 Final Determination Quantitative Analysis
The United States (U.S.) Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2007 would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2004. The final analysis considered each of the 44 addenda to ANSI/ASHRAE/IESNA Standard 90.1-2004 that were included in ANSI/ASHRAE/IESNA Standard 90.1-2007. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from Standard 90.1-2004 were reviewed by DOE, and their combined impact on a suite of 15 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOEs final determination. However, out of the 44 addenda, 9 were preliminarily determined to have measureable and quantifiable impact.
ANSI/ASHRAE/INESNA Standard 90.1-2007 Final Determination Quantitative Analysis
M. Halverson (author) / B. Liu (author) / E. Richman (author) / D. Winiarski (author)
2011
80 pages
Report
No indication
English
Codes & Standards - ANSI-ASHRAE-IESNA Standard 90.1 evolves with lighting control systems.
Online Contents | 2008
MEP Roundtable - ASHRAE 90.1 — 2007 and beyond
Online Contents | 2010