A platform for research: civil engineering, architecture and urbanism
Special Study of Precast Concrete Tunnel Liner Demonstration: Lexington Market Tunnels, Baltimore, Maryland
During the period from the Spring of 1976 through early 1980, a demonstration project was carried out for precast segmented concrete tunnel liner in the Lexington Market Section of the Baltimore Regional Rapid Transit System. In the project, twin tunnels, each approximately 1550 feet in length, were lined with concrete in the outbound tunnel and steel in the inbound tunnel. Length, ground conditions, tunneling techniques, and crews were comparable for the two tunnels. This study and report of findings were commissioned by the Urban Mass Transportation Administration to provide government and industry personnel with a comprehensive evaluation of precast segmented concrete liner for use in transit tunnels in the United States. The performance of the two liner systems was documented in considerable detail through a combination of instrumentation, record keeping, photography, and personal observation. This performance and the program by which it was determined, are described in detail in this report.
Special Study of Precast Concrete Tunnel Liner Demonstration: Lexington Market Tunnels, Baltimore, Maryland
During the period from the Spring of 1976 through early 1980, a demonstration project was carried out for precast segmented concrete tunnel liner in the Lexington Market Section of the Baltimore Regional Rapid Transit System. In the project, twin tunnels, each approximately 1550 feet in length, were lined with concrete in the outbound tunnel and steel in the inbound tunnel. Length, ground conditions, tunneling techniques, and crews were comparable for the two tunnels. This study and report of findings were commissioned by the Urban Mass Transportation Administration to provide government and industry personnel with a comprehensive evaluation of precast segmented concrete liner for use in transit tunnels in the United States. The performance of the two liner systems was documented in considerable detail through a combination of instrumentation, record keeping, photography, and personal observation. This performance and the program by which it was determined, are described in detail in this report.
Special Study of Precast Concrete Tunnel Liner Demonstration: Lexington Market Tunnels, Baltimore, Maryland
W. D. Wightman (author) / S. Calabrese (author) / E. L. Foster (author)
1980
268 pages
Report
No indication
English
Engineering Index Backfile | 1956
|Engineering Index Backfile | 1955
|Engineering Index Backfile | 1955
|CSX Tunnel Fire, Baltimore, Maryland
NTIS | 2001
|Selection and design of corrosion protection liner for precast concrete segment tunnel liner
British Library Conference Proceedings | 2002
|