A platform for research: civil engineering, architecture and urbanism
Fire endurance tests were conducted on two floor/ceiling assemblies intended for use in modular housing. The floors were of plywood deck with vinyl or carpet overlay on light gage steel C joists. In the floor-ceiling assembly, the ceiling was separately supported on its own joists. During the tests the floors were loaded to represent the dead weight of structural parts bearing on them and a live load application of 40 psf. The test results are valid only for floors of similar construction loaded at or below the stress level developed by this loading. Failure of the floor with the protective ceiling assembly occurred by flame-through to the unexposed surface at 29 min., with extensive structural failure (collapse under load) following at 33 min. The unprotected floor over the crawl space had a flame through at 3 1/4 min., and structural failure following at 3 3/4 min. (Author Modified Abstract)
Fire endurance tests were conducted on two floor/ceiling assemblies intended for use in modular housing. The floors were of plywood deck with vinyl or carpet overlay on light gage steel C joists. In the floor-ceiling assembly, the ceiling was separately supported on its own joists. During the tests the floors were loaded to represent the dead weight of structural parts bearing on them and a live load application of 40 psf. The test results are valid only for floors of similar construction loaded at or below the stress level developed by this loading. Failure of the floor with the protective ceiling assembly occurred by flame-through to the unexposed surface at 29 min., with extensive structural failure (collapse under load) following at 33 min. The unprotected floor over the crawl space had a flame through at 3 1/4 min., and structural failure following at 3 3/4 min. (Author Modified Abstract)
Fire Endurance Tests of Plywood of Steel Joist Floor Assemblies, With and Without Ceiling. (Test Numbers 492 and 497)
1973
40 pages
Report
No indication
English
Building Standards & Codes , Housing , Floors , Fire resistance , Plywood , Modular structures , Fire safety , Tests , Performance evaluation , Ceilings(Architecture) , Steel , Joists , Loads(Forces) , Failure , Fires , Housing and urban development research , Plywood floor assemblies , Modular housing , Fire tests
Fire Resistance of Steel C-Joist Floor Assemblies
British Library Online Contents | 2010
|Fire endurance modeling of wood floor/ceiling assemblies
British Library Conference Proceedings | 1995
|Fire Resistance of Wood Joist Floor Assemblies
British Library Online Contents | 2008
|