A platform for research: civil engineering, architecture and urbanism
As a part of the testing and evaluation activities in Operation Breakthrough, a standard fire test conforming to ASTM E 119 was performed at the National Bureau of Standards on a wall assembly where half represented a nonbearing single exterior wall, as found in single family detached housing, and the other half represented a nonbearing double wall assembly for an interdwelling separation which would occur at the interface of two parallel adjacent modules. Each wall contained a layer of gypsum board as an interior (room) surface and a layer of plywood as an exterior surface, and was framed with nominal 2 x 4 in. wood studs on 16 in. centers. No structural load was applied during the test. (Modified author abstract)
As a part of the testing and evaluation activities in Operation Breakthrough, a standard fire test conforming to ASTM E 119 was performed at the National Bureau of Standards on a wall assembly where half represented a nonbearing single exterior wall, as found in single family detached housing, and the other half represented a nonbearing double wall assembly for an interdwelling separation which would occur at the interface of two parallel adjacent modules. Each wall contained a layer of gypsum board as an interior (room) surface and a layer of plywood as an exterior surface, and was framed with nominal 2 x 4 in. wood studs on 16 in. centers. No structural load was applied during the test. (Modified author abstract)
Fire Endurance Test of Plywood-Faced Exterior Walls for Single Family Housing
B. C. Son (author)
1973
25 pages
Report
No indication
English
Materials Sciences , Building Standards & Codes , Walls , Fire tests , Gypsum , Panels , Plywood , Residential buildings , Fire safety , Durability , Time , Failure , Temperature , Fire endurance tests , Breakthrough operation , Interdwelling walls , Single family dwellings , Gypsum board , Detached dwellings , Modular construction
Engineering Index Backfile | 1966
|Use of plastic-faced plywood as concrete forms
Engineering Index Backfile | 1949
Fire Resistance of Exterior Walls: Model and Full-scale Test
British Library Conference Proceedings | 2005
|