The thermal conductivity of a single concrete mortar specimen with varying moisture content is reported in the temperature range from 95 to 320K. The measurements were made in a guarded hot plate apparatus (ASTM C-177). Moisture migration caused by temperature gradients was minimized by studying the saturated specimen in the low-temperature region. Specimen moisture content and concomitant thermal conductivity were altered by imposing low-pressure, high temperature conditions on the specimen. The effect of changing the moisture content is discussed.
The thermal conductivity of a single concrete mortar specimen with varying moisture content is reported in the temperature range from 95 to 320K. The measurements were made in a guarded hot plate apparatus (ASTM C-177). Moisture migration caused by temperature gradients was minimized by studying the saturated specimen in the low-temperature region. Specimen moisture content and concomitant thermal conductivity were altered by imposing low-pressure, high temperature conditions on the specimen. The effect of changing the moisture content is discussed.
Thermal Conductivity of Concrete Mortar
L. L. Sparks (author)
1983
9 pages
Report
No indication
English
Construction Materials, Components, & Equipment , Construction Equipment, Materials, & Supplies , Thermal conductivity , Concrete , Moisture content , Measurement , Low temperature tests , High temperature tests , Mortars(Material) , Pressure , Temperature gradients , Reprints , Guarded hot plate apparatus
Thermal Conductivity of Traditional Mortar
British Library Conference Proceedings | 1992
|