Seismic Durability of Retrofitted R.C. Columns
The seismic performances of three retrofitted and one control, half scale, circular, reinforced concrete columns were studied. The columns were 10-ft. high, 18-in. diameter cantilevers. The longitudinal flexural steel was spliced to the foundation dowels just above the fixed base. A concentric axial load was continually applied during testing. The free ends of the cantilevers were translated to produce a maximum displacement of four times that necessary to produce yield in the longitudinal reinforcing steel. The loading was repeated with both positive and negative displacements in a quasi-static manner until the lateral forces required to produce these displacements approached zero. The measure of seismic durability used was the number of such cycles that a column sustained before losing structural integrity. The arrangement was intended to model that of bridge columns constructed during the 1960s. Three columns were retrofitted with prestressed, externally located circular hoops at intervals along the lower 4 ft. The spacing and size of these ties varied from column to column. The control column sustained less than two cycles before losing structural integrity; the retrofitted columns sustained a minimum of twelve cycles.
Seismic Durability of Retrofitted R.C. Columns
The seismic performances of three retrofitted and one control, half scale, circular, reinforced concrete columns were studied. The columns were 10-ft. high, 18-in. diameter cantilevers. The longitudinal flexural steel was spliced to the foundation dowels just above the fixed base. A concentric axial load was continually applied during testing. The free ends of the cantilevers were translated to produce a maximum displacement of four times that necessary to produce yield in the longitudinal reinforcing steel. The loading was repeated with both positive and negative displacements in a quasi-static manner until the lateral forces required to produce these displacements approached zero. The measure of seismic durability used was the number of such cycles that a column sustained before losing structural integrity. The arrangement was intended to model that of bridge columns constructed during the 1960s. Three columns were retrofitted with prestressed, externally located circular hoops at intervals along the lower 4 ft. The spacing and size of these ties varied from column to column. The control column sustained less than two cycles before losing structural integrity; the retrofitted columns sustained a minimum of twelve cycles.
Seismic Durability of Retrofitted R.C. Columns
H. L. Coffman (author) / C. B. Brown (author) / M. L. Marsh (author)
1991
54 pages
Report
No indication
English
Highway Engineering , Construction Equipment, Materials, & Supplies , Earthquake resistant structures , Reinforced concrete , Concrete durability , Columns(Supports) , Highway bridges , Seismic waves , Structural members , Earthquake engineering , Concrete construction , Ductility , Earthquake resistance , Reinforcement(Structures) , Displacement
Seismic Durability of Retrofitted Reinforced-Concrete Columns
British Library Online Contents | 1993
|Seismic Durability of Retrofitted Reinforced-Concrete Columns.
Online Contents | 1993
|Seismic Behaviour of FRP-Retrofitted Concrete Columns
ASCE | 2001
|Seismic performance of RC columns retrofitted with CFRP Strips
British Library Conference Proceedings | 2007
|Seismic performance of reinforced concrete columns retrofitted by various methods
Online Contents | 2017
|