A platform for research: civil engineering, architecture and urbanism
Measured Transfer Lengths of 0.7 in. (17.8 mm) Strands for Pretensioned Beams
The use of 0.7 in. (17.8 mm), Grade 270 (1860) prestressing strands has advantages over 0.5 and 0.6 in. (12.7 and 15.22 mm) strands. This study provides design guidelines for estimating transfer length of 0.7 in. (17.8 mm) strands. Sixteen pretensioned concrete beams using a single prestressing strand were fabricated with conventional concrete and self-consolidating concrete. The concrete strengths at 1 day ranged from 5.9 to 9.2 ksi (40.7 to 63.4 MPa). Transfer lengths were determined using concrete surface strains along with the Average Maximum Strain Method. Initial strand end slips were also measured for predicting transfer length at release using an empirical formula. Experimental results indicated ACI 318 and AASHTO specifications are applicable for estimating transfer length of 0.7 in. (17.8 mm) strands at release and at 28 days. The results also showed that a coefficient of 2.32 was the most appropriate value for estimating transfer lengths at release from initial strand end slips.
Measured Transfer Lengths of 0.7 in. (17.8 mm) Strands for Pretensioned Beams
The use of 0.7 in. (17.8 mm), Grade 270 (1860) prestressing strands has advantages over 0.5 and 0.6 in. (12.7 and 15.22 mm) strands. This study provides design guidelines for estimating transfer length of 0.7 in. (17.8 mm) strands. Sixteen pretensioned concrete beams using a single prestressing strand were fabricated with conventional concrete and self-consolidating concrete. The concrete strengths at 1 day ranged from 5.9 to 9.2 ksi (40.7 to 63.4 MPa). Transfer lengths were determined using concrete surface strains along with the Average Maximum Strain Method. Initial strand end slips were also measured for predicting transfer length at release using an empirical formula. Experimental results indicated ACI 318 and AASHTO specifications are applicable for estimating transfer length of 0.7 in. (17.8 mm) strands at release and at 28 days. The results also showed that a coefficient of 2.32 was the most appropriate value for estimating transfer lengths at release from initial strand end slips.
Measured Transfer Lengths of 0.7 in. (17.8 mm) Strands for Pretensioned Beams
Royce W Floyd (author) / Canh N Dang / J R Martí-Vargas / W Micah Hale
ACI structural journal ; 113
2016
Article (Journal)
English
Measured Development Lengths of 0.7 in. (17.8 mm) Strands for Pretensioned Beams
Online Contents | 2016
|Measured Development Lengths of 0.7 in. (17.8 mm) Strands for Pretensioned Beams
British Library Online Contents | 2016
|Shear Performance of Pretensioned Concrete I-Girders Employing 0.7 in. (17.8 mm) Strands
Online Contents | 2017
|Transfer Lengths in Pretensioned Concrete Measured Using Various Sensing Technologies
DOAJ | 2019
|Transfer Lengths in Pretensioned Concrete Measured Using Various Sensing Technologies
Springer Verlag | 2019
|