A platform for research: civil engineering, architecture and urbanism
Uncertainties in Grout Penetrability Measurements; Evaluation and Comparison of Filter pump, Penetrability Meter and Short Slot
Abstract To measure grout penetrability in fractured hard rock, various measuring instruments have been developed over the years. Penetrability meter and Filter pump have been designed to use in both the lab and the field. Short slot has been applicable mainly in the lab due to its complexity. The fact, that these instruments have been built based on different assumptions, limitations, and test conditions, makes their results occasionally in contradict. Deficiency in design of the instruments as well as the methods of evaluating grout penetrability is additionally a basis for uncertainty in results. This study is an experimental effort to determine and thoroughly perceive the nature of the most governing uncertainties in grout penetrability measurements. The test apparatus, procedure, and method used to evaluate the grout penetrability in both Penetrability meter and Filter pump were thus modified. The aim was to control the corresponding uncertainties and make their limitations and test conditions as similar as possible with the ones in Short slot. The results suggested that to obtain a more realistic evaluation of the grout penetrability, measurement should be accomplished at both the high and the low pressures with sufficient grout volume using Short slot. Moreover, application of both Filter pump and Penetrability meter is no longer recommended due to the revealed uncertainties.
Uncertainties in Grout Penetrability Measurements; Evaluation and Comparison of Filter pump, Penetrability Meter and Short Slot
Abstract To measure grout penetrability in fractured hard rock, various measuring instruments have been developed over the years. Penetrability meter and Filter pump have been designed to use in both the lab and the field. Short slot has been applicable mainly in the lab due to its complexity. The fact, that these instruments have been built based on different assumptions, limitations, and test conditions, makes their results occasionally in contradict. Deficiency in design of the instruments as well as the methods of evaluating grout penetrability is additionally a basis for uncertainty in results. This study is an experimental effort to determine and thoroughly perceive the nature of the most governing uncertainties in grout penetrability measurements. The test apparatus, procedure, and method used to evaluate the grout penetrability in both Penetrability meter and Filter pump were thus modified. The aim was to control the corresponding uncertainties and make their limitations and test conditions as similar as possible with the ones in Short slot. The results suggested that to obtain a more realistic evaluation of the grout penetrability, measurement should be accomplished at both the high and the low pressures with sufficient grout volume using Short slot. Moreover, application of both Filter pump and Penetrability meter is no longer recommended due to the revealed uncertainties.
Uncertainties in Grout Penetrability Measurements; Evaluation and Comparison of Filter pump, Penetrability Meter and Short Slot
Nejad Ghafar, A. (author) / Ali Akbar, S. (author) / Al-Naddaf, M. (author) / Draganovic, A. (author) / Larsson, S. (author)
2017
Article (Journal)
English
Online Contents | 2017
|Filtration and penetrability of cement-based grout: Study performed with a short slot
British Library Online Contents | 2011
|Filtration and penetrability of cement-based grout: Study performed with a short slot
Online Contents | 2011
|Springer Verlag | 2022
|