A platform for research: civil engineering, architecture and urbanism
Analysis of co-located measurements made with a LaCoste&Romberg Graviton-EG gravimeter and two superconducting gravimeters at Strasbourg (France) and Yebes (Spain)
Abstract Two experiments of intercomparison between the LaCoste&Romberg Graviton-EG1194 spring gravimeter and the superconducting gravimeters SG-026 and OSG-064, operating respectively at J9-Strasbourg (France) and CDT-Yebes (Spain), were analyzed. The main objective was to check the instrumental response of the spring meter, both in amplitude and phase as well as its time stability. A general conclusion is that normalization factors have been obtained with a similar ratio for main diurnal constituent O1 at both observing sites. The accuracy of scale factors was determined at the level of 0.03 % (at J9-Strasbourg) and 0.1 % (at CDT-Yebes). For the semidiurnal constituent M2, slight differences were found at J9-Strasbourg, which would require further investigations. Site effects were also demonstrated by considering the different response of the spring gravimeter to tilts and atmospheric pressure variations at both sites.
Analysis of co-located measurements made with a LaCoste&Romberg Graviton-EG gravimeter and two superconducting gravimeters at Strasbourg (France) and Yebes (Spain)
Abstract Two experiments of intercomparison between the LaCoste&Romberg Graviton-EG1194 spring gravimeter and the superconducting gravimeters SG-026 and OSG-064, operating respectively at J9-Strasbourg (France) and CDT-Yebes (Spain), were analyzed. The main objective was to check the instrumental response of the spring meter, both in amplitude and phase as well as its time stability. A general conclusion is that normalization factors have been obtained with a similar ratio for main diurnal constituent O1 at both observing sites. The accuracy of scale factors was determined at the level of 0.03 % (at J9-Strasbourg) and 0.1 % (at CDT-Yebes). For the semidiurnal constituent M2, slight differences were found at J9-Strasbourg, which would require further investigations. Site effects were also demonstrated by considering the different response of the spring gravimeter to tilts and atmospheric pressure variations at both sites.
Analysis of co-located measurements made with a LaCoste&Romberg Graviton-EG gravimeter and two superconducting gravimeters at Strasbourg (France) and Yebes (Spain)
Arnoso, J. (author) / Riccardi, U. (author) / Hinderer, J. (author) / Córdoba, B. (author) / Montesinos, F. G. (author)
2014
Article (Journal)
English
On the sensitivity characteristics of Lacoste & Romberg gravimeter (model G)
Online Contents | 1985
|Airborne LaCoste & Romberg gravimetry: a space domain approach
Online Contents | 2006
|Grossräumige Schweremessungen mit LaCoste-Romberg-Gravimetern, 1964 - 1970
UB Braunschweig | 1971
|Airborne LaCoste & Romberg gravimetry: a space domain approach
Online Contents | 2006
|