A platform for research: civil engineering, architecture and urbanism
Techno-economic analysis of a PV/T waste heat–driven compound ejector-heat pump for simultaneous data centre cooling and district heating using low global warming potential refrigerants
Abstract A comprehensive techno-economic evaluation is evaluated based on an innovative compound ejector-heat pump system with PV/T (photovoltaic thermal) waste heat-driven. The aim of the system is simultaneous data centre cooling and waste heat recovery for district heating to reduce residential greenhouse gas emissions. The new system avoids the ejector pump by combining PV/T waste heat with an evaporative-condenser as an ejector driving force, considering several low global warming potential alternatives to R134a. The simulation indicates that the proposed system presents a remarkable difference in all investigated refrigerants’ overall system coefficient of performance (COP). Particularly, R515B presents the highest increase in COP, 54% and 49% in cooling and heating modes, respectively. It also provides the highest electricity consumption reduction, 84.1 MWh yearly. Moreover, the system improves the data centre power usage effectiveness (PUE) index from 10 to 19%. In financial terms, the shortest payback period (6.3 years) is obtained with R515B, followed by R515A and R1234ze(E).
Techno-economic analysis of a PV/T waste heat–driven compound ejector-heat pump for simultaneous data centre cooling and district heating using low global warming potential refrigerants
Abstract A comprehensive techno-economic evaluation is evaluated based on an innovative compound ejector-heat pump system with PV/T (photovoltaic thermal) waste heat-driven. The aim of the system is simultaneous data centre cooling and waste heat recovery for district heating to reduce residential greenhouse gas emissions. The new system avoids the ejector pump by combining PV/T waste heat with an evaporative-condenser as an ejector driving force, considering several low global warming potential alternatives to R134a. The simulation indicates that the proposed system presents a remarkable difference in all investigated refrigerants’ overall system coefficient of performance (COP). Particularly, R515B presents the highest increase in COP, 54% and 49% in cooling and heating modes, respectively. It also provides the highest electricity consumption reduction, 84.1 MWh yearly. Moreover, the system improves the data centre power usage effectiveness (PUE) index from 10 to 19%. In financial terms, the shortest payback period (6.3 years) is obtained with R515B, followed by R515A and R1234ze(E).
Techno-economic analysis of a PV/T waste heat–driven compound ejector-heat pump for simultaneous data centre cooling and district heating using low global warming potential refrigerants
Al-Sayyab, Ali Khalid Shaker (author) / Navarro-Esbrí, Joaquín (author) / Barragán-Cervera, Angel (author) / Mota-Babiloni, Adrián (author)
2022
Article (Journal)
Electronic Resource
English
BKL:
43.47
Globale Umweltprobleme
/
43.47$jGlobale Umweltprobleme
Transient simulation of heat pumps using low global warming potential refrigerants
Taylor & Francis Verlag | 2015
|Evaluation of the Data Centre Waste Heat Potential in District Heating in Latvia
BASE | 2024
|Performance ranking of refrigerants with low global warming potential
Taylor & Francis Verlag | 2015
|