A platform for research: civil engineering, architecture and urbanism
Experimental and numerical study on post-fire behavior of high-strength Q460 steel columns
Experimental study and finite element modeling on the structural behavior of high-strength Q460 steel columns after being exposed to ISO-834 standard fire are presented. Two section shapes were considered, namely welded H-shaped section and welded box-section. The experiment composes of two stages: heating and cooling stage of the specimens and compressive test on the specimen after fire exposure. The temperatures experienced in the specimens were recorded during both the heating and cooling phases, as well as the load–deflection curves, load–axial displacement curves, load–rotation curves, load–strain curves, and failure modes in the steel columns were measured during the compressive tests. Three-dimensional finite element models were also established by employing the program ANSYS to study the post-fire behavior of high-strength Q460 steel columns. The finite element models were used to investigate the effects of key parameters on the residual load-bearing capacity of high-strength Q460 steel columns, following exposure to the ISO-834 standard fire. The investigated parameters included heating time, cooling methods, and slenderness ratio. Finally, a simplified design approach was proposed for predicting the residual load-bearing capacity of high-strength Q460 steel columns after being exposed to ISO-834 standard fire.
Experimental and numerical study on post-fire behavior of high-strength Q460 steel columns
Experimental study and finite element modeling on the structural behavior of high-strength Q460 steel columns after being exposed to ISO-834 standard fire are presented. Two section shapes were considered, namely welded H-shaped section and welded box-section. The experiment composes of two stages: heating and cooling stage of the specimens and compressive test on the specimen after fire exposure. The temperatures experienced in the specimens were recorded during both the heating and cooling phases, as well as the load–deflection curves, load–axial displacement curves, load–rotation curves, load–strain curves, and failure modes in the steel columns were measured during the compressive tests. Three-dimensional finite element models were also established by employing the program ANSYS to study the post-fire behavior of high-strength Q460 steel columns. The finite element models were used to investigate the effects of key parameters on the residual load-bearing capacity of high-strength Q460 steel columns, following exposure to the ISO-834 standard fire. The investigated parameters included heating time, cooling methods, and slenderness ratio. Finally, a simplified design approach was proposed for predicting the residual load-bearing capacity of high-strength Q460 steel columns after being exposed to ISO-834 standard fire.
Experimental and numerical study on post-fire behavior of high-strength Q460 steel columns
Wang, Weiyong (author) / Liu, Tianzi (author)
Advances in Structural Engineering ; 19 ; 1873-1888
2016-12-01
16 pages
Article (Journal)
Electronic Resource
English
Experimental and numerical study on post-fire behavior of high-strength Q460 steel columns
Online Contents | 2016
|Experimental study on post-fire mechanical properties of high strength Q460 steel
British Library Online Contents | 2015
|Experimental study on post-fire mechanical properties of high strength Q460 steel
British Library Online Contents | 2015
|Experimental study on post-fire mechanical performances of high strength steel Q460
SAGE Publications | 2021
|