A platform for research: civil engineering, architecture and urbanism
This paper deals with the investigation of wind loading on the pyramidal roof structure of the Church of St Michael in Newton, Wirral, Cheshire, England, by wind tunnel tests on a 1/48 scale model. The roof of the model was flat in the peripheral region of the building while in the inner region there was a grouping of four pyramidal roofs. Wind tunnel experiments were carried out; wind pressure distribution and contours of wind pressure on all surfaces of the pyramid roofs were determined for four principal wind directions. The average suctions on the roof were evaluated. The highest point suction encountered was — 4q whilst the maximum average suction on the roof was —0·86q. The results obtained from wind tunnel tests were used for the design of pyramidal roof structures and roof coverings for which localised high suctions were very significant.
This paper deals with the investigation of wind loading on the pyramidal roof structure of the Church of St Michael in Newton, Wirral, Cheshire, England, by wind tunnel tests on a 1/48 scale model. The roof of the model was flat in the peripheral region of the building while in the inner region there was a grouping of four pyramidal roofs. Wind tunnel experiments were carried out; wind pressure distribution and contours of wind pressure on all surfaces of the pyramid roofs were determined for four principal wind directions. The average suctions on the roof were evaluated. The highest point suction encountered was — 4q whilst the maximum average suction on the roof was —0·86q. The results obtained from wind tunnel tests were used for the design of pyramidal roof structures and roof coverings for which localised high suctions were very significant.
Wind Loading on a Pyramidal Roof Structure
Dutt, A. J. (author)
International Journal of Space Structures ; 1 ; 105-110
1985-06-01
6 pages
Article (Journal)
Electronic Resource
English
Elsevier | 1988
|British Library Conference Proceedings | 1994
|Recent developments in plastics stressed-skin pyramidal roof systems
Engineering Index Backfile | 1965
|Evaluation of Roof Fasteners Under Dynamic Wind Loading
British Library Conference Proceedings | 1994
|Wind Loading for Roof Trusses Using ASCE Standard
Online Contents | 1997
|