A platform for research: civil engineering, architecture and urbanism
A Pushover Seismic Analysis and Retrofitting Method Applied to Low-Rise RC School Buildings
The proposed method, called the Taiwan Earthquake Assessment for Structures by Pushover Analysis (TEASPA), is a modified capacity spectrum method developed in the NCREE handbook after the 1999 Chi-Chi earthquake. In this study, the evaluation of TEASPA is carried out using results from an experimental campaign comprised of two pushover tests inlow-rise reinforced concrete (RC) school buildings and the ASCE 41 capacity spectrum method. In addition, three problems related to retrofitting design are also discussed. Those are the removal of short columns in the structure, the optimal selection of the RC jacketing's position, and waterproofing problems in the RC jacketing method. The base shear-roof displacement curve, peak ground acceleration, and failure mechanism are calculated from each analysis. The results show that TEASPA is capable of providing accurate results for assessing a low-rise RC building's capacity and is more appropriate to pushover tests. Moreover, the solutions related to retrofitting problems are provided.
A Pushover Seismic Analysis and Retrofitting Method Applied to Low-Rise RC School Buildings
The proposed method, called the Taiwan Earthquake Assessment for Structures by Pushover Analysis (TEASPA), is a modified capacity spectrum method developed in the NCREE handbook after the 1999 Chi-Chi earthquake. In this study, the evaluation of TEASPA is carried out using results from an experimental campaign comprised of two pushover tests inlow-rise reinforced concrete (RC) school buildings and the ASCE 41 capacity spectrum method. In addition, three problems related to retrofitting design are also discussed. Those are the removal of short columns in the structure, the optimal selection of the RC jacketing's position, and waterproofing problems in the RC jacketing method. The base shear-roof displacement curve, peak ground acceleration, and failure mechanism are calculated from each analysis. The results show that TEASPA is capable of providing accurate results for assessing a low-rise RC building's capacity and is more appropriate to pushover tests. Moreover, the solutions related to retrofitting problems are provided.
A Pushover Seismic Analysis and Retrofitting Method Applied to Low-Rise RC School Buildings
Hsiao, Fu-Pei (author) / Oktavianus, Yusak (author) / Ou, Yu-Chen (author) / Luu, Cong-Hieu (author) / Hwang, Shyh-Jiann (author)
Advances in Structural Engineering ; 18 ; 311-324
2015-03-01
14 pages
Article (Journal)
Electronic Resource
English
A Pushover Seismic Analysis and Retrofitting Method Applied to Low-Rise RC School Buildings
Online Contents | 2015
|Theme: Seismic Retrofitting - Analysis for seismic retrofitting of buildings
Online Contents | 2002
|Seismic response of asymmetrical buildings using pushover analysis
British Library Conference Proceedings | 1997
|Seismic evaluation and retrofitting of an existing building in Athens using pushover analysis
BASE | 2019
|