A platform for research: civil engineering, architecture and urbanism
Flexural Responses of Prestressed Hybrid Wide Flange Composite Girders
Abstract In this study, prestressed hybrid wide flange (PHWF) composite girders were proposed, and full-scale flexural tests were conducted to evaluate their structural performances. This new proposed girder system was developed and designed to effectively resist external loads considering the actual construction sequences. Two specimens with and without shear connectors were fabricated and tested to examine the effect of the shear connectors for achieving the fully-composite behaviors between a cast-in-place (CIP) concrete and the prefabricated prestressed steel–concrete composite girder. The test results showed that sufficient flexural strengths and deformation capacities can be obtained in both types of PHWF composite girders with and without shear connectors. To reflect the actual construction stages of the proposed PHWF composite girder, nonlinear flexural analyses were proposed considering the prestress effect and segmental effect before and after composite with the CIP concrete, respectively. The observed and analysis results of strain behaviors of the PHWF girder specimens were also compared and discussed in detail.
Flexural Responses of Prestressed Hybrid Wide Flange Composite Girders
Abstract In this study, prestressed hybrid wide flange (PHWF) composite girders were proposed, and full-scale flexural tests were conducted to evaluate their structural performances. This new proposed girder system was developed and designed to effectively resist external loads considering the actual construction sequences. Two specimens with and without shear connectors were fabricated and tested to examine the effect of the shear connectors for achieving the fully-composite behaviors between a cast-in-place (CIP) concrete and the prefabricated prestressed steel–concrete composite girder. The test results showed that sufficient flexural strengths and deformation capacities can be obtained in both types of PHWF composite girders with and without shear connectors. To reflect the actual construction stages of the proposed PHWF composite girder, nonlinear flexural analyses were proposed considering the prestress effect and segmental effect before and after composite with the CIP concrete, respectively. The observed and analysis results of strain behaviors of the PHWF girder specimens were also compared and discussed in detail.
Flexural Responses of Prestressed Hybrid Wide Flange Composite Girders
Han, Sun-Jin (author) / Lee, Deuck Hang (author) / Oh, Jae-Yuel (author) / Choi, Seung-Ho (author) / Kim, Kang Su (author)
2018-08-02
16 pages
Article (Journal)
Electronic Resource
English
Flexural Responses of Prestressed Hybrid Wide Flange Composite Girders
Springer Verlag | 2018
|Flexural strength of tubular flange girders
Online Contents | 2009
|Flexural strength of tubular flange girders
Online Contents | 2009
|