A platform for research: civil engineering, architecture and urbanism
Seismic Response of RC Framed Buildings Designed According to Eurocodes
In order to ensure that a structure does not collapse when subjected to the action of strong ground motions, modern codes include prescriptions in order to guarantee the ductile behavior of the elements and of the whole structure. Obviously, it would be of special importance for the designer to know during the design process the extent of damage that the structure will suffer under the seismic action specified by the design spectrum and also the probability of occurrence of different states of behaviour. The incremental nonlinear static analysis procedure used in this paper allows formulating a new, simplified, seismic damage index and damage thresholds associated with five limit states. The seismic behavior of a set of regular reinforced concrete buildings designed according to the EC-2/EC-8 prescriptions for a high seismic hazard level is then studied using the proposed damage index and damage states. Fragility curves and damage probability matrices corresponding to the performance point are calculated for the studied buildings. The obtained results show that the collapse damage state is not reached in the buildings designed according the prescriptions of EC-2/EC-8 and also that the damage does not exceed the irreparable damage limit state.
Seismic Response of RC Framed Buildings Designed According to Eurocodes
In order to ensure that a structure does not collapse when subjected to the action of strong ground motions, modern codes include prescriptions in order to guarantee the ductile behavior of the elements and of the whole structure. Obviously, it would be of special importance for the designer to know during the design process the extent of damage that the structure will suffer under the seismic action specified by the design spectrum and also the probability of occurrence of different states of behaviour. The incremental nonlinear static analysis procedure used in this paper allows formulating a new, simplified, seismic damage index and damage thresholds associated with five limit states. The seismic behavior of a set of regular reinforced concrete buildings designed according to the EC-2/EC-8 prescriptions for a high seismic hazard level is then studied using the proposed damage index and damage states. Fragility curves and damage probability matrices corresponding to the performance point are calculated for the studied buildings. The obtained results show that the collapse damage state is not reached in the buildings designed according the prescriptions of EC-2/EC-8 and also that the damage does not exceed the irreparable damage limit state.
Seismic Response of RC Framed Buildings Designed According to Eurocodes
Computational Methods
Papadrakakis, Manolis (editor) / Fragiadakis, Michalis (editor) / Lagaros, Nikos D. (editor) / Vielma, Juan Carlos (author) / Barbat, Alex (author) / Oller, Sergio (author)
2010-11-16
20 pages
Article/Chapter (Book)
Electronic Resource
English
Seismic Response of RC Framed Buildings Designed According to Eurocodes
British Library Conference Proceedings | 2011
|Seismic fragility of RC framed and wall-frame buildings designed to the EN-Eurocodes
British Library Online Contents | 2012
|Seismic response of asymmetric frame building designed according to eurocodes
British Library Conference Proceedings | 2001
|Seismic Fragility of RC Buildings Designed to Eurocodes 2 and 8
British Library Conference Proceedings | 2014
|Masonry Buildings, Seismic Performance, and Eurocodes
British Library Conference Proceedings | 2014
|