Mitigation of Seismic Pounding Observed in Adjacent Buildings with Fluid Viscous Damper
Seismic pounding between closely spaced building structures is one among the main causes of severe building damages observed in seismically proven regions. Due to the earthquake-induced vibrations, the buildings which are adjacent to each other with dissimilar dynamic characteristics will move out of phase resulting in the collision as there would be no energy dissipation system to accommodate the relative motions. Seismic pounding can be prevented by passive structural control of energy dissipation systems, i.e., dampers. The current study aims to mitigate the seismic pounding observed in the adjacent buildings connected with fluid viscous dampers (FVDs). G+14 and G+9 multistoried adjacent buildings are modeled and analyzed using ETABS 2017. Two stories are connected with one viscous damper. Adjacent buildings with similar height (G+14 storied) and varying height (G+14 & G+9 storied) connected with FVDs subjected to El Centro earthquake are studied. Nonlinear time history analysis is carried out. Considering displacement and seismic gap as the main parameters, adjacent buildings with similar and different height connected with and without FVDs are compared.
Mitigation of Seismic Pounding Observed in Adjacent Buildings with Fluid Viscous Damper
Seismic pounding between closely spaced building structures is one among the main causes of severe building damages observed in seismically proven regions. Due to the earthquake-induced vibrations, the buildings which are adjacent to each other with dissimilar dynamic characteristics will move out of phase resulting in the collision as there would be no energy dissipation system to accommodate the relative motions. Seismic pounding can be prevented by passive structural control of energy dissipation systems, i.e., dampers. The current study aims to mitigate the seismic pounding observed in the adjacent buildings connected with fluid viscous dampers (FVDs). G+14 and G+9 multistoried adjacent buildings are modeled and analyzed using ETABS 2017. Two stories are connected with one viscous damper. Adjacent buildings with similar height (G+14 storied) and varying height (G+14 & G+9 storied) connected with FVDs subjected to El Centro earthquake are studied. Nonlinear time history analysis is carried out. Considering displacement and seismic gap as the main parameters, adjacent buildings with similar and different height connected with and without FVDs are compared.
Mitigation of Seismic Pounding Observed in Adjacent Buildings with Fluid Viscous Damper
Lecture Notes in Civil Engineering
Nandagiri, Lakshman (editor) / Narasimhan, M. C. (editor) / Marathe, Shriram (editor) / Dinesh, S.V. (editor) / Patil, Basanagouda I. (author) / Biradar, Bapugouda B. (author) / Doddamani, Rashmi (author)
2021-09-03
21 pages
Article/Chapter (Book)
Electronic Resource
English
Preventing Seismic Pounding of Adjacent Structures Using Viscous Wall Damper Device
Springer Verlag | 2018
|Seismic Pounding Mitigation of Two Adjacent Reinforced Concrete Buildings with Bracing System
Springer Verlag | 2023
|Springer Verlag | 2024
|Seismic pounding of adjacent buildings considering torsional effects
Springer Verlag | 2024
|