A platform for research: civil engineering, architecture and urbanism
Parametric Study of Slender Columns Retrofitted with NSM CFRP Rods
Corrosion of steel bars in reinforced concrete (RC) due to environmental exposure results in service life and durability reduction and subsequent premature failure of structures. Columns are considered as critical components of a structure. Partial or full loss of columns’ steel reinforcement due to corrosion can potentially lead to the collapse of the entire structure. An effective retrofit procedure is required to restore the performance of these damaged columns. The present numerical study investigates the use of near-surface mounted (NSM) CFRP rods as a retrofit technique for eccentrically loaded slender columns that partially or fully have lost their internal steel reinforcement due to corrosive environment. The proposed numerical model is corroborated with experimental results available in the literature. A parametric study was conducted to study the effectiveness of the NSM CFRP rods retrofitting to structurally compensate for the lost corroded steel reinforcement of as-built columns for ten different scenarios. The performance of retrofitted columns was assessed through axial load versus moment response plots. The results indicate that the NSM CFRP rods were able to regain the reduction in strength caused by the loss of internal steel reinforcement of damaged columns. Whereas in some scenarios, axial load and moment carrying capacities were increased.
Parametric Study of Slender Columns Retrofitted with NSM CFRP Rods
Corrosion of steel bars in reinforced concrete (RC) due to environmental exposure results in service life and durability reduction and subsequent premature failure of structures. Columns are considered as critical components of a structure. Partial or full loss of columns’ steel reinforcement due to corrosion can potentially lead to the collapse of the entire structure. An effective retrofit procedure is required to restore the performance of these damaged columns. The present numerical study investigates the use of near-surface mounted (NSM) CFRP rods as a retrofit technique for eccentrically loaded slender columns that partially or fully have lost their internal steel reinforcement due to corrosive environment. The proposed numerical model is corroborated with experimental results available in the literature. A parametric study was conducted to study the effectiveness of the NSM CFRP rods retrofitting to structurally compensate for the lost corroded steel reinforcement of as-built columns for ten different scenarios. The performance of retrofitted columns was assessed through axial load versus moment response plots. The results indicate that the NSM CFRP rods were able to regain the reduction in strength caused by the loss of internal steel reinforcement of damaged columns. Whereas in some scenarios, axial load and moment carrying capacities were increased.
Parametric Study of Slender Columns Retrofitted with NSM CFRP Rods
Lecture Notes in Civil Engineering
Ilki, Alper (editor) / Ispir, Medine (editor) / Inci, Pinar (editor) / Salgado, Rafael A. (author) / Parvin, Azadeh (author)
International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering ; 2021 ; Istanbul, Turkey
10th International Conference on FRP Composites in Civil Engineering ; Chapter: 32 ; 373-386
2021-11-27
14 pages
Article/Chapter (Book)
Electronic Resource
English
Stress and strain behavior of slender concrete columns retrofitted with CFRP composites
Tema Archive | 2009
|Stress and Strain Behavior of Slender Concrete Columns Retrofitted with CFRP Composites
British Library Online Contents | 2009
|Ductility of RC Columns Retrofitted with CFRP Sheet
British Library Conference Proceedings | 1998
|Seismic performance of RC columns retrofitted with CFRP Strips
British Library Conference Proceedings | 2007
|Performance of CFRP Retrofitted Concrete Columns at Low Temperatures
British Library Conference Proceedings | 1996
|