A platform for research: civil engineering, architecture and urbanism
Performance analysis of combined cooling heating and power (CCHP) exhaust waste heat coupled air source heat pump system
Abstract To achieve the deep recovery of exhaust waste heat, a combined cooling heating and power (CCHP) dynamic exhaust low temperature waste heat coupled air source heat pump system is proposed in this paper. Aspen Plus software was used to simulate the system and analyze the effects of the recyclable waste heat of the system, the coefficient of performance (COP) of the heat pump and the impact of the primary energy utilization rate. The results showed that under the design condition, the exhaust waste heat of CCHP system was 1.22 kW, the recyclable waste heat of heat pump system was up to 1.07 kW, the exhaust waste heat recovery rate was 87.7%. The COP was up to 4.66, increased 39.5%. The primary energy utilization efficiency was increased by 3.9%. It solves the problem of heat pump evaporator frosting and poor performance of low temperature in cold regions. This study provides an important reference for the combined and efficient application of CCHP systems and heat pump units.
Performance analysis of combined cooling heating and power (CCHP) exhaust waste heat coupled air source heat pump system
Abstract To achieve the deep recovery of exhaust waste heat, a combined cooling heating and power (CCHP) dynamic exhaust low temperature waste heat coupled air source heat pump system is proposed in this paper. Aspen Plus software was used to simulate the system and analyze the effects of the recyclable waste heat of the system, the coefficient of performance (COP) of the heat pump and the impact of the primary energy utilization rate. The results showed that under the design condition, the exhaust waste heat of CCHP system was 1.22 kW, the recyclable waste heat of heat pump system was up to 1.07 kW, the exhaust waste heat recovery rate was 87.7%. The COP was up to 4.66, increased 39.5%. The primary energy utilization efficiency was increased by 3.9%. It solves the problem of heat pump evaporator frosting and poor performance of low temperature in cold regions. This study provides an important reference for the combined and efficient application of CCHP systems and heat pump units.
Performance analysis of combined cooling heating and power (CCHP) exhaust waste heat coupled air source heat pump system
Hong, Wenpeng (author) / Hao, Jing (author) / Wang, Jiayu (author) / Teng, Da (author) / Jin, Xu (author)
Building Simulation ; 12 ; 563-571
2019-05-21
9 pages
Article (Journal)
Electronic Resource
English
British Library Conference Proceedings | 2012
|British Library Online Contents | 2008
|