A platform for research: civil engineering, architecture and urbanism
Pullout and bond of glass-fibre rods embedded in concrete and cement grout
Abstract Consideration is being given to replacing steel rebars with glass-fibre rods in some specific areas, particularly those in which premature failure due to corrosion has been observed. This paper presents the results of an experimental study of pullout behaviour and bond characteristics of glass-fibre rods embedded in normal and high-strength concretes and in cement grout. The results of the study show that glass-fibre rod bond strength is about 12 MPa and the optimal anchored length approximately 10 times the rod diameter. The average modification factor of top-cast reinforcement was found to be equal to 1.23 and 1.18 for normal and high-strength concrete, respectively. Other considerations, such as bond slip, are also discussed in the paper. Comparisons with steel reinforcement are made whenever appropriate.
Resume Cet article présente les résultats d’une étude expérimentale qui a trait à l’évaluation des capacités d’adhérence d’une nouvelle tige à base de fibres de verre intoduite pour être utilisée comme armature à béton et comme tige d’ancrage. Plusieurs aspects sont abordés dans l’étude: (i) la résistance d’adhérence, (ii) la longueur optimale de développement d’ancrage, (iii) l’effet de la résistance du béton, (iv) la relation adhérence-glissement et (v) l’influence de la position de la tige d’armature. Il ressort de l’étude que la tige possède des caractéristiques d’adhérence suffisantes pour être utilisée comme armature à béton et tige d’ancrage injectée au coulis de ciment. En particulier, il a été trouvé que la résistance à l’arrachement est de l’ordre de 12 MPa pour les bétons et 4 MPa pour le coulis de ciment. La longueur de développement d’ancrage capable de résister à 700 MPa est de l’ordre de 20d et 30d et celle pour résister à 500 MPa de l’ordre de 10d et 20d, pour les bétons et le coulis respectivement, d étant le diamètre de la tige. Le coefficient de majoration associé à la tige placée en haut est de l’ordre de 1,2.
Pullout and bond of glass-fibre rods embedded in concrete and cement grout
Abstract Consideration is being given to replacing steel rebars with glass-fibre rods in some specific areas, particularly those in which premature failure due to corrosion has been observed. This paper presents the results of an experimental study of pullout behaviour and bond characteristics of glass-fibre rods embedded in normal and high-strength concretes and in cement grout. The results of the study show that glass-fibre rod bond strength is about 12 MPa and the optimal anchored length approximately 10 times the rod diameter. The average modification factor of top-cast reinforcement was found to be equal to 1.23 and 1.18 for normal and high-strength concrete, respectively. Other considerations, such as bond slip, are also discussed in the paper. Comparisons with steel reinforcement are made whenever appropriate.
Resume Cet article présente les résultats d’une étude expérimentale qui a trait à l’évaluation des capacités d’adhérence d’une nouvelle tige à base de fibres de verre intoduite pour être utilisée comme armature à béton et comme tige d’ancrage. Plusieurs aspects sont abordés dans l’étude: (i) la résistance d’adhérence, (ii) la longueur optimale de développement d’ancrage, (iii) l’effet de la résistance du béton, (iv) la relation adhérence-glissement et (v) l’influence de la position de la tige d’armature. Il ressort de l’étude que la tige possède des caractéristiques d’adhérence suffisantes pour être utilisée comme armature à béton et tige d’ancrage injectée au coulis de ciment. En particulier, il a été trouvé que la résistance à l’arrachement est de l’ordre de 12 MPa pour les bétons et 4 MPa pour le coulis de ciment. La longueur de développement d’ancrage capable de résister à 700 MPa est de l’ordre de 20d et 30d et celle pour résister à 500 MPa de l’ordre de 10d et 20d, pour les bétons et le coulis respectivement, d étant le diamètre de la tige. Le coefficient de majoration associé à la tige placée en haut est de l’ordre de 1,2.
Pullout and bond of glass-fibre rods embedded in concrete and cement grout
Chaallal, O. (author) / Benmokrane, B. (author)
Materials and Structures ; 26 ; 167-175
1993-04-01
9 pages
Article (Journal)
Electronic Resource
English
Pullout and bond of glass-fibre rods embedded in concrete and cement grout
Online Contents | 1993
|Pullout and bond of glass-fibre rods embedded in concrete and cement grout
Online Contents | 1993
|Pullout and bond of glass-fibre rods embedded in concrete and cement grout
British Library Online Contents | 1993
|Pullout Bond Properties of Fiber-Reinforced Polymer Tendons to Grout
British Library Online Contents | 2002
|Pullout Bond Properties of Fiber-Reinforced Polymer Tendons to Grout
Online Contents | 2002
|