Bond of reinforcement in eccentric pullout silica fume concrete specimens
Abstract The objectives of the study were to investigate the role of specimen type and specimen size on the effect of silica fume on bond strength of reinforcing bars, and to evaluate the effect of bar size and concrete confinement on the anchorage characteristics of the reinforcing bars in silica fume concrete. Forty-eight eccentric pullout specimens were tested. The variables were the percentage replacement by weight of cement by silica, the concrete cover over the reinforcing bar, and the bar size. Failure of the specimens was governed by splitting of the concrete cover over the anchored bar. Test results indicated that as the percentage of silica fume increased, the maximum load capacity and the stiffness of the load-slip curve of the anchored bar decreased, regardless of bar size or the concrete cover used. The results showed that concrete confinement slightly improved the bond resistance in concrete containing more than 10 percent silica fume.
Résumé Les objectifs de cette étude concement l'influence de la nature et de la taille des échantillons sur l'action de la fumée de silice dans les forces de liaison entre le béton et les armatures d'acier. L'évaluation de l'effet du diamètre des armatures et du confinement du béton sur les caractéristiques d'ancrage des armatures utilisées avec du béton avec comme adjuvant la fumée de silice a été également effectuée. Quarante-huit échantillons ont été testés par le biais d'une extraction excentrée, les variables étant le pourcentage de substitution du ciment par des fumées de silice (en poids), la couverture de béton et la diminution des armatures. Le mode de rupture des échantillons est dominé par l'éclatement de la couche de béton recouvrant les armatures. Les résultats obtenus montrent que plus le pourcentage de la fumée de silice monte, plus la capacité maximale de charge ainsi que la courbe glissement—charge appliqué des armatures ancrées diminuent, quel que soit le diamètre des armatures ou l'enrobage du béton. Un léger confinement, dans le cas d'un béton à plus de 10 pour cent de fumée de silice, sert à augmenter légèrement ces forces de liaison.
Bond of reinforcement in eccentric pullout silica fume concrete specimens
Abstract The objectives of the study were to investigate the role of specimen type and specimen size on the effect of silica fume on bond strength of reinforcing bars, and to evaluate the effect of bar size and concrete confinement on the anchorage characteristics of the reinforcing bars in silica fume concrete. Forty-eight eccentric pullout specimens were tested. The variables were the percentage replacement by weight of cement by silica, the concrete cover over the reinforcing bar, and the bar size. Failure of the specimens was governed by splitting of the concrete cover over the anchored bar. Test results indicated that as the percentage of silica fume increased, the maximum load capacity and the stiffness of the load-slip curve of the anchored bar decreased, regardless of bar size or the concrete cover used. The results showed that concrete confinement slightly improved the bond resistance in concrete containing more than 10 percent silica fume.
Résumé Les objectifs de cette étude concement l'influence de la nature et de la taille des échantillons sur l'action de la fumée de silice dans les forces de liaison entre le béton et les armatures d'acier. L'évaluation de l'effet du diamètre des armatures et du confinement du béton sur les caractéristiques d'ancrage des armatures utilisées avec du béton avec comme adjuvant la fumée de silice a été également effectuée. Quarante-huit échantillons ont été testés par le biais d'une extraction excentrée, les variables étant le pourcentage de substitution du ciment par des fumées de silice (en poids), la couverture de béton et la diminution des armatures. Le mode de rupture des échantillons est dominé par l'éclatement de la couche de béton recouvrant les armatures. Les résultats obtenus montrent que plus le pourcentage de la fumée de silice monte, plus la capacité maximale de charge ainsi que la courbe glissement—charge appliqué des armatures ancrées diminuent, quel que soit le diamètre des armatures ou l'enrobage du béton. Un léger confinement, dans le cas d'un béton à plus de 10 pour cent de fumée de silice, sert à augmenter légèrement ces forces de liaison.
Bond of reinforcement in eccentric pullout silica fume concrete specimens
Hamad, Bilal S. (author) / Sabbah, Saad M. (author)
Materials and Structures ; 31 ; 707-713
1998-12-01
7 pages
Article (Journal)
Electronic Resource
English
Bond of reinforcement in eccentric pullout silica fume concrete specimens
British Library Online Contents | 1998
|Bond of reinforcement in eccentric pullout silica fume concrete specimens
Online Contents | 1998
|TECHNICAL REPORTS - Bond of reinforcement in eccentric pullout silica fume concrete specimens
Online Contents | 1998
|British Library Online Contents | 2001
|