New non-destructive method for linear polarisation resistance corrosion rate measurement
Corrosion of steel reinforcement is one of the most common causes of end service life in reinforced concrete structures. Corrosion is initiated and propagates unseen beneath the concrete cover and it is difficult to evaluate the severity of the problem. The most promising electrochemical method is the Linear Polarisation Resistance method which can provide a direct evaluation of the instantaneous rate of corrosion. The main drawback to this technique is that it requires a localized breakout of the concrete cover to provide an electrical connection to the steel reinforcement. This article describes an adaptation of the LPR method and the four-point Wenner resistivity method to give an assessment of the rate of steel corrosion without the requirement for a direct connection to the reinforcement. The measurements have been performed in cooperation with Construction and Infrastructure Group in University of Liverpool.
New non-destructive method for linear polarisation resistance corrosion rate measurement
Corrosion of steel reinforcement is one of the most common causes of end service life in reinforced concrete structures. Corrosion is initiated and propagates unseen beneath the concrete cover and it is difficult to evaluate the severity of the problem. The most promising electrochemical method is the Linear Polarisation Resistance method which can provide a direct evaluation of the instantaneous rate of corrosion. The main drawback to this technique is that it requires a localized breakout of the concrete cover to provide an electrical connection to the steel reinforcement. This article describes an adaptation of the LPR method and the four-point Wenner resistivity method to give an assessment of the rate of steel corrosion without the requirement for a direct connection to the reinforcement. The measurements have been performed in cooperation with Construction and Infrastructure Group in University of Liverpool.
New non-destructive method for linear polarisation resistance corrosion rate measurement
Nowa nieniszcząca metoda pomiaru stopnia korozji z użyciem polaryzacji liniowej
Sadowski, Ł. (author)
Archives of Civil and Mechanical Engineering ; 10 ; 109-116
2010-06-01
8 pages
Article (Journal)
Electronic Resource
English
New non-destructive method for linear polarisation resistance corrosion rate measurement
British Library Online Contents | 2010
|Environmental influences on linear polarisation corrosion rate measurement in reinforced concrete
British Library Conference Proceedings | 2000
|Environmental Influences on Linear Polarisation Corrosion Rate Measurement in Reinforced Concrete
British Library Conference Proceedings | 2000
|British Library Online Contents | 2003
|