A platform for research: civil engineering, architecture and urbanism
Preliminary Italian Maps of the Expected Annual Losses of Residential Code-Conforming Buildings
The expected annual loss (EAL) is a metric often used to quantify the risk, including that related to seismic behavior of structures. It allows to combine the annual probability that the considered structure experiences any damage level, with the expected value of the consequences of such damages. In Italy, to promote seismic risk mitigation, a tax relief for retrofitting costs of existing buildings has been introduced. One of the two criteria adopted to demonstrate the improvement of the seismic performance of the structure after the retrofit is the comparison of (a simplified assessment of) the EAL before and after the retrofitting. In this context, it is interesting to quantify the EAL of code-conforming residential buildings of different structural typologies and supposed located in each Italian municipality. This kind of study descends from a recent Italian research project named RINTC – Rischio implicito delle strutture progettate secondo le NTC – that aims at the evaluation of the seismic reliability inherent to design according to the current Italian building code. Selecting some of the structures analyzed in the RINTC project, national maps of EAL for four code-conforming buildings are computed. Such structures are three- and six-storey reinforced concrete (RC) frame, infilled, buildings, and two- and three-storey unreinforced masonry (URM) buildings. The EALs are obtained combing the results of probabilistic seismic hazard analyses, performed in accordance with an authoritative source model for Italy, with the fragility functions derived for two performance (i.e., damage) levels, namely usability-preventing damage and global collapse. Results, following those of the RINTC project, generally show that: (i) EALs vary with the site and the considered structural typology; (ii) three-storey RC and two-storey URM are generally associated to the lowest EAL while the largest are often related to three-storey URM.
Preliminary Italian Maps of the Expected Annual Losses of Residential Code-Conforming Buildings
The expected annual loss (EAL) is a metric often used to quantify the risk, including that related to seismic behavior of structures. It allows to combine the annual probability that the considered structure experiences any damage level, with the expected value of the consequences of such damages. In Italy, to promote seismic risk mitigation, a tax relief for retrofitting costs of existing buildings has been introduced. One of the two criteria adopted to demonstrate the improvement of the seismic performance of the structure after the retrofit is the comparison of (a simplified assessment of) the EAL before and after the retrofitting. In this context, it is interesting to quantify the EAL of code-conforming residential buildings of different structural typologies and supposed located in each Italian municipality. This kind of study descends from a recent Italian research project named RINTC – Rischio implicito delle strutture progettate secondo le NTC – that aims at the evaluation of the seismic reliability inherent to design according to the current Italian building code. Selecting some of the structures analyzed in the RINTC project, national maps of EAL for four code-conforming buildings are computed. Such structures are three- and six-storey reinforced concrete (RC) frame, infilled, buildings, and two- and three-storey unreinforced masonry (URM) buildings. The EALs are obtained combing the results of probabilistic seismic hazard analyses, performed in accordance with an authoritative source model for Italy, with the fragility functions derived for two performance (i.e., damage) levels, namely usability-preventing damage and global collapse. Results, following those of the RINTC project, generally show that: (i) EALs vary with the site and the considered structural typology; (ii) three-storey RC and two-storey URM are generally associated to the lowest EAL while the largest are often related to three-storey URM.
Preliminary Italian Maps of the Expected Annual Losses of Residential Code-Conforming Buildings
Lect. Notes in Networks, Syst.
Calabrò, Francesco (editor) / Della Spina, Lucia (editor) / Piñeira Mantiñán, María José (editor) / Chioccarelli, Eugenio (author) / Pacifico, Adriana (author) / Iervolino, Iunio (author)
INTERNATIONAL SYMPOSIUM: New Metropolitan Perspectives ; 2022 ; Reggio Calabria, Italy
2022-08-25
10 pages
Article/Chapter (Book)
Electronic Resource
English
Seismic Reliability of Code-Conforming Italian Buildings
Taylor & Francis Verlag | 2018
|Evolution of Seismic Reliability of Code-Conforming Italian Buildings
Taylor & Francis Verlag | 2023
|Developing a Direct Approach for Estimating Expected Annual Losses of Italian Buildings
Taylor & Francis Verlag | 2022
|Seismic Fragility of Code-conforming Italian Buildings Based on SDoF Approximation
Taylor & Francis Verlag | 2021
|Masonry Italian Code-Conforming Buildings. Part 1: Case Studies and Design Methods
Taylor & Francis Verlag | 2018
|