Room Corner Fire Growth Studies of Plywood Lining Material Under Fully Ventilated Condition
Full scale compartment fire studies have been conducted with plywood board as lining material on walls. The compartment was of size 3.6 m long × 2.4 m wide × 2.4 m high with a doorway of size 0.8 m wide × 2.0 m high with hood as per ISO 9705. Standard propane burner ignition source of size 0.3 m × 0.3 m was set to produce a heat release rate (HRR) of 40 kW in the first 5 min and of 160 kW in the next 10 min at the room corner. K–type thermocouples, heat flux sensor, pressure transducers and flue gas analyzers were used to measure temperatures, radiation, differential pressure and toxic species concentrations of hot gases at different locations within the compartment and hood. Peak heat release rates, flashover condition and gas concentrations were measured in transient condition and compared with tenability limits of fire hazards.
Room Corner Fire Growth Studies of Plywood Lining Material Under Fully Ventilated Condition
Full scale compartment fire studies have been conducted with plywood board as lining material on walls. The compartment was of size 3.6 m long × 2.4 m wide × 2.4 m high with a doorway of size 0.8 m wide × 2.0 m high with hood as per ISO 9705. Standard propane burner ignition source of size 0.3 m × 0.3 m was set to produce a heat release rate (HRR) of 40 kW in the first 5 min and of 160 kW in the next 10 min at the room corner. K–type thermocouples, heat flux sensor, pressure transducers and flue gas analyzers were used to measure temperatures, radiation, differential pressure and toxic species concentrations of hot gases at different locations within the compartment and hood. Peak heat release rates, flashover condition and gas concentrations were measured in transient condition and compared with tenability limits of fire hazards.
Room Corner Fire Growth Studies of Plywood Lining Material Under Fully Ventilated Condition
J. Inst. Eng. India Ser. A
Aravind Kumar, A. (author) / Kumar, Rajiv (author) / Ansari, A. A. (author)
Journal of The Institution of Engineers (India): Series A ; 102 ; 545-551
2021-06-01
7 pages
Article (Journal)
Electronic Resource
English
Behavior of Plywood Lining in Full Scale Room Fire Tests
British Library Online Contents | 1999
|A Room-Corner Fire Growth & Zone Model for Lining Materials
British Library Conference Proceedings | 1998
|Corner Fire Growth in a Room With a Combustible Lining
British Library Conference Proceedings | 2003
|Effects of Surface Flame Spread of Plywood Lining on Enclosure Fire in a Modified ISO Room
Online Contents | 2003
|Effects of Surface Flame Spread of Plywood Lining on Enclosure Fire in a Modified ISO Room
British Library Online Contents | 2003
|