A platform for research: civil engineering, architecture and urbanism
Seismic vulnerability assessment of masonry building supported by STRP isolators
Scrap tire rubber pad (STRP) isolators are made from scrap automobile tires, which are expected to be a low-cost material for earthquake-resistant design of low-to-medium-rise buildings in developing countries. This paper describes the seismic vulnerability of a unbonded STRP (U-STRP) base-isolated masonry building using the finite element method. The three-dimensional model of the U-STRP isolators is placed between the foundation and the building without any bonding between them. As a result, the inertia force of the building is transferred to the foundation through the friction. Two alternative versions of the U-STRP isolator: strip-shaped and square-shaped, are analyzed, which have comparable geometric and stiffness properties. The fidelity of the U-STRP isolator model is confirmed using the numerical analysis and experimental results. The seismic vulnerability of the masonry base-isolated building is determined using the pushover analysis and the fragility curves and then compared to that of the identical fixed-base building. The findings show that masonry buildings with uniformly distributed square-shaped U-STRP isolators suffer low damage and base shear compared to those of the same size of strip-shaped U-STRP isolators. The U-STRP base-isolated masonry building has superior seismic performance to that of an identical fixed-base building, and a square-shaped U-STRP is more effective than the strip-shaped isolator.
Seismic vulnerability assessment of masonry building supported by STRP isolators
Scrap tire rubber pad (STRP) isolators are made from scrap automobile tires, which are expected to be a low-cost material for earthquake-resistant design of low-to-medium-rise buildings in developing countries. This paper describes the seismic vulnerability of a unbonded STRP (U-STRP) base-isolated masonry building using the finite element method. The three-dimensional model of the U-STRP isolators is placed between the foundation and the building without any bonding between them. As a result, the inertia force of the building is transferred to the foundation through the friction. Two alternative versions of the U-STRP isolator: strip-shaped and square-shaped, are analyzed, which have comparable geometric and stiffness properties. The fidelity of the U-STRP isolator model is confirmed using the numerical analysis and experimental results. The seismic vulnerability of the masonry base-isolated building is determined using the pushover analysis and the fragility curves and then compared to that of the identical fixed-base building. The findings show that masonry buildings with uniformly distributed square-shaped U-STRP isolators suffer low damage and base shear compared to those of the same size of strip-shaped U-STRP isolators. The U-STRP base-isolated masonry building has superior seismic performance to that of an identical fixed-base building, and a square-shaped U-STRP is more effective than the strip-shaped isolator.
Seismic vulnerability assessment of masonry building supported by STRP isolators
Asian J Civ Eng
Zisan, Md Basir (author) / Haque, Md. Naimul (author) / Hasan, Md. Abul (author)
Asian Journal of Civil Engineering ; 24 ; 121-136
2023-01-01
16 pages
Article (Journal)
Electronic Resource
English
Seismic vulnerability assessment of a monumental masonry building
Online Contents | 2017
|Seismic Performance Analysis of Masonry Building with Scrap Tyre Pad Isolators
Springer Verlag | 2023
|