A platform for research: civil engineering, architecture and urbanism
Cross-Facility Validation of Dynamic Centrifuge Testing
This paper compares the results of dynamic centrifuge tests on shallow foundations conducted at two different geotechnical facilities, IFSTTAR (Institut français des sciences et technologies des transports, de l’aménagement et des réseaux, formerly LCPC), France and Cambridge University, U.K. Both facilities ran tests on a single degree of freedom model structure with its shallow foundation located on dry sand and subjected to dynamic shaking. Measurements were taken at both facilities allowing direct comparisons to be made. Fundamentally the results obtained were found to agree well via comparison of soil amplification profiles and moment-rotation cycles. However, higher frequency components agreed less favourably. This variation is thought to be due to a mismatch between the dynamic properties of the model containers. In this series of tests the higher frequency components are not of great importance and therefore the variation is insignificant, however, in future tests when earthquake signals with higher frequency components are input it may become an issue requiring further investigation.
Cross-Facility Validation of Dynamic Centrifuge Testing
This paper compares the results of dynamic centrifuge tests on shallow foundations conducted at two different geotechnical facilities, IFSTTAR (Institut français des sciences et technologies des transports, de l’aménagement et des réseaux, formerly LCPC), France and Cambridge University, U.K. Both facilities ran tests on a single degree of freedom model structure with its shallow foundation located on dry sand and subjected to dynamic shaking. Measurements were taken at both facilities allowing direct comparisons to be made. Fundamentally the results obtained were found to agree well via comparison of soil amplification profiles and moment-rotation cycles. However, higher frequency components agreed less favourably. This variation is thought to be due to a mismatch between the dynamic properties of the model containers. In this series of tests the higher frequency components are not of great importance and therefore the variation is insignificant, however, in future tests when earthquake signals with higher frequency components are input it may become an issue requiring further investigation.
Cross-Facility Validation of Dynamic Centrifuge Testing
Geotechnical,Geological
Fardis, Michael N. (editor) / Rakicevic, Zoran T. (editor) / Cilingir, Ulas (author) / Haigh, Stuart (author) / Heron, Charles (author) / Madabhushi, Gopal (author) / Chazelas, Jean-Louis (author) / Escoffier, Sandra (author)
Role of Seismic Testing Facilities in Performance-Based Earthquake Engineering ; Chapter: 5 ; 83-98
2011-09-20
16 pages
Article/Chapter (Book)
Electronic Resource
English
Cross-Facility Validation of Dynamic Centrifuge Testing
British Library Conference Proceedings | 2012
|Nishimatsu dynamic geotechnical centrifuge facility
British Library Conference Proceedings | 1998
|British Library Conference Proceedings | 1994
|Portuguese new centrifuge facility
British Library Conference Proceedings | 1997
|Dynamic capabilities of the Wright Laboratory geotechnical centrifuge facility
British Library Conference Proceedings | 1994
|