Clean Agent Total Flooding Fire Extinguishing Systems
Abstract Total flooding clean agents and systems were developed in response to the regulation of Halon 1301 under the Montreal Protocol and its amendments culminated in the phase-out of production of halons in the developed countries on December 31, 1993. This regulation engendered tremendous research and development efforts across the world in a search for replacements and alternatives. Since that time on the order of 15 total flooding, clean agent alternatives to Halon 1301 have been commercialized, and development continues on others. In addition to cleanagent total flooding gaseous alternatives, new technologies, such as water mist and fine solid particulate, are being introduced. This chapter focuses on total flooding clean agent halon replacements.
Clean Agent Total Flooding Fire Extinguishing Systems
Abstract Total flooding clean agents and systems were developed in response to the regulation of Halon 1301 under the Montreal Protocol and its amendments culminated in the phase-out of production of halons in the developed countries on December 31, 1993. This regulation engendered tremendous research and development efforts across the world in a search for replacements and alternatives. Since that time on the order of 15 total flooding, clean agent alternatives to Halon 1301 have been commercialized, and development continues on others. In addition to cleanagent total flooding gaseous alternatives, new technologies, such as water mist and fine solid particulate, are being introduced. This chapter focuses on total flooding clean agent halon replacements.
Clean Agent Total Flooding Fire Extinguishing Systems
DiNenno, Philip J. (author) / Forssell, Eric W. (author)
SFPE Handbook of Fire Protection Engineering ; 1483-1530
Fifth Edition
2016-01-01
48 pages
Article/Chapter (Book)
Electronic Resource
English
Global Warming Potential , Fire Size , Thermal Decomposition Product , Atmospheric Lifetime , Ozone Depletion Potential Engineering , Civil Engineering , Mechanical Engineering , Safety in Chemistry, Dangerous Goods , Materials Science, general , Engineering Thermodynamics, Heat and Mass Transfer , Industrial and Organizational Psychology
NFPA 2001 : standard on clean agent fire extinguishing systems
TIBKAT | 2015
|Analysis of Hold Time Models for Total Flooding Clean Extinguishing Agents
British Library Online Contents | 2008
|Clean Fire Extinguishing Agents: Part 2
British Library Online Contents | 1993
Clean Fire Extinguishing Agents: Part 1
British Library Online Contents | 1993
Mobile fire extinguishing device for battery fire using invasive fire extinguishing agent
European Patent Office | 2025