A platform for research: civil engineering, architecture and urbanism
Simulation and analysis on thermodynamic performance of surface water source heat pump system
Abstract This work established a thermodynamic performance model of a heat pump system containing a heat pump unit model, an air conditioning cooling and heating load calculation model, a heat exchanger model and a water pump performance model based on mass and energy balances. The thermodynamic performance of a surface water source heat pump air conditioning system was simulated and verified by comparing the simulation results to an actual engineering project. In addition, the effects of the surface water temperature, heat exchanger structure and surface water pipeline transportation system on the thermodynamic performance of the heat pump air conditioning system were analyzed. Under the simulated conditions in this paper with a cooling load of 3400 kW, the results showed that a 1 °C decrease in the surface water temperature leads to a 2.3 percent increase in the coefficient of performance; furthermore, an additional 100 m of length for the closed-loop surface water heat exchanger tube leads to a 0.08 percent increase in the coefficient of performance. To decrease the system energy consumption, the optimal working point should be specified according to the surface water transportation length.
Simulation and analysis on thermodynamic performance of surface water source heat pump system
Abstract This work established a thermodynamic performance model of a heat pump system containing a heat pump unit model, an air conditioning cooling and heating load calculation model, a heat exchanger model and a water pump performance model based on mass and energy balances. The thermodynamic performance of a surface water source heat pump air conditioning system was simulated and verified by comparing the simulation results to an actual engineering project. In addition, the effects of the surface water temperature, heat exchanger structure and surface water pipeline transportation system on the thermodynamic performance of the heat pump air conditioning system were analyzed. Under the simulated conditions in this paper with a cooling load of 3400 kW, the results showed that a 1 °C decrease in the surface water temperature leads to a 2.3 percent increase in the coefficient of performance; furthermore, an additional 100 m of length for the closed-loop surface water heat exchanger tube leads to a 0.08 percent increase in the coefficient of performance. To decrease the system energy consumption, the optimal working point should be specified according to the surface water transportation length.
Simulation and analysis on thermodynamic performance of surface water source heat pump system
Lv, Nan (author) / Zhang, Qing (author) / Chen, Zhenqian (author) / Wu, Dongsheng (author)
Building Simulation ; 10 ; 65-73
2016-08-08
9 pages
Article (Journal)
Electronic Resource
English
Simulation and analysis on thermodynamic performance of surface water source heat pump system
Online Contents | 2017
|DOAJ | 2018
|Analysis of Water Heat Pollution of Thermal Discharge in Surface Water Source Heat Pump System
British Library Conference Proceedings | 2013
|Energy Efficiency of Water Transportation System for Surface Water Source Heat Pump