A platform for research: civil engineering, architecture and urbanism
Characterization of polymer modified bituminous roofing membranes using chromatography
Abstract This is part of a broad study to characterize polymer modified bituminous roofing materials studied for seam performance. Ten different commercial roofing materials, three of atactic polypropylene (APP) modified bitumen and seven of styrene-butadine-styrene copolymer (SBS) modified bitumen, were studied using high performance liquid chromatography for the analysis of the original bitumen binders and high performance gel permeation chromatography for the qualitative and quantitative analysis of the polymers. The results show that the oxidized bitumen has the highest asphaltene content at about 30%. The asphaltene content of the original bitumen in APP products is higher than in SBS products. The difference in the amount of polymer in each product is not great, and no correlation with seam strength is observed. The degradation of the polymer, which refers to the decrease in molecular weight or the increase in molecular weight distribution can be identified.
Resume Le but de cette étude était de caractériser les lés d'étanchéité de bitume polymère sur lesquels on avait examiné les performances des joints soudés. Dix lés d'étanchéitè du commerce, dont trois à base de bitume modifié par du polypropylène atactique (APP) et sept à base de bitumen modifié par un copolymère styrène-butadiène-styrène (SBS) one été étudiés à l'aide de la chromatographie haute performance en phase liquide pour l'analyse des liants bitumineux d'origine, et à l'aide de la chromatographie haute performance par perméation sur gel pour l'analyse qualitative et quantitative des polymères. Les résultats montrent que le bitume oxydé présente la teneur en asphaltène la plus élevée avec environ 30%. La teneur en asphaltène du bitume original des produits APP est plus élevée que celles des produits SBS. Les différences de teneur en polymère entre chaque produit étaient faibles et aucune corrélation entre ces différences et la résistance des joints n'a été observée. La dégradation du polymère, qui s'exprime par une diminution de poids moléculaire ou par une augmentation de la distribution du poids moléculaire, peut être identifiée.
Characterization of polymer modified bituminous roofing membranes using chromatography
Abstract This is part of a broad study to characterize polymer modified bituminous roofing materials studied for seam performance. Ten different commercial roofing materials, three of atactic polypropylene (APP) modified bitumen and seven of styrene-butadine-styrene copolymer (SBS) modified bitumen, were studied using high performance liquid chromatography for the analysis of the original bitumen binders and high performance gel permeation chromatography for the qualitative and quantitative analysis of the polymers. The results show that the oxidized bitumen has the highest asphaltene content at about 30%. The asphaltene content of the original bitumen in APP products is higher than in SBS products. The difference in the amount of polymer in each product is not great, and no correlation with seam strength is observed. The degradation of the polymer, which refers to the decrease in molecular weight or the increase in molecular weight distribution can be identified.
Resume Le but de cette étude était de caractériser les lés d'étanchéité de bitume polymère sur lesquels on avait examiné les performances des joints soudés. Dix lés d'étanchéitè du commerce, dont trois à base de bitume modifié par du polypropylène atactique (APP) et sept à base de bitumen modifié par un copolymère styrène-butadiène-styrène (SBS) one été étudiés à l'aide de la chromatographie haute performance en phase liquide pour l'analyse des liants bitumineux d'origine, et à l'aide de la chromatographie haute performance par perméation sur gel pour l'analyse qualitative et quantitative des polymères. Les résultats montrent que le bitume oxydé présente la teneur en asphaltène la plus élevée avec environ 30%. La teneur en asphaltène du bitume original des produits APP est plus élevée que celles des produits SBS. Les différences de teneur en polymère entre chaque produit étaient faibles et aucune corrélation entre ces différences et la résistance des joints n'a été observée. La dégradation du polymère, qui s'exprime par une diminution de poids moléculaire ou par une augmentation de la distribution du poids moléculaire, peut être identifiée.
Characterization of polymer modified bituminous roofing membranes using chromatography
Oba, Koichi (author) / Hugener, Martin (author)
Materials and Structures ; 28 ; 534-544
1995-11-01
11 pages
Article (Journal)
Electronic Resource
English
Characterization of polymer modified bituminous roofing membranes using chromatography
Online Contents | 1995
|Characterization of polymer modified bituminous roofing membranes using chromatography
British Library Online Contents | 1995
|Characterization of polymer modified bituminous roofing membranes using chromatography
Online Contents | 1995
|Characterization of polymer modified bituminous roofing membranes using thermal analysis
Online Contents | 1995
|Characterization of polymer modified bituminous roofing membranes using thermal analysis
British Library Online Contents | 1995
|