A platform for research: civil engineering, architecture and urbanism
Performance of Steel Kerf Plates as Shear Connector for Cross-Laminated Timber-Concrete Composite Systems
In this paper, experimental investigations of the performance of Timber-Concrete Composite (TCC) systems with steel kerf plates as shear connectors are presented. The stiffness, strength, and failure modes of small-scale TCC specimens with steel kerf plates were evaluated in quasi-static monotonic tests. The specimens were comprised of 245 mm thick, 7-ply CLT panels with 150 mm concrete topping connected with steel plates. The embedment depths of the steel plates in the CLT were varied from 35 to 90 mm to investigate the performance variation. Eighteen tests were conducted with six replicates from each type. The load-deformations and connector slips at the CLT-concrete interfaces were measured. Results showed that load carrying capacity and stiffness of all test series were comparable and that the shallow 35 mm steel plate embedment depth into CLT resulted in sufficient composite action for the TCC composites. The steel kerf plates showed excellent performance and can be deemed a promising and economical solution for shear connectors in TCC members.
Performance of Steel Kerf Plates as Shear Connector for Cross-Laminated Timber-Concrete Composite Systems
In this paper, experimental investigations of the performance of Timber-Concrete Composite (TCC) systems with steel kerf plates as shear connectors are presented. The stiffness, strength, and failure modes of small-scale TCC specimens with steel kerf plates were evaluated in quasi-static monotonic tests. The specimens were comprised of 245 mm thick, 7-ply CLT panels with 150 mm concrete topping connected with steel plates. The embedment depths of the steel plates in the CLT were varied from 35 to 90 mm to investigate the performance variation. Eighteen tests were conducted with six replicates from each type. The load-deformations and connector slips at the CLT-concrete interfaces were measured. Results showed that load carrying capacity and stiffness of all test series were comparable and that the shallow 35 mm steel plate embedment depth into CLT resulted in sufficient composite action for the TCC composites. The steel kerf plates showed excellent performance and can be deemed a promising and economical solution for shear connectors in TCC members.
Performance of Steel Kerf Plates as Shear Connector for Cross-Laminated Timber-Concrete Composite Systems
Lecture Notes in Civil Engineering
Walbridge, Scott (editor) / Nik-Bakht, Mazdak (editor) / Ng, Kelvin Tsun Wai (editor) / Shome, Manas (editor) / Alam, M. Shahria (editor) / el Damatty, Ashraf (editor) / Lovegrove, Gordon (editor) / Shahnewaz, Md (author) / Jackson, Robert (author) / Tannert, Thomas (author)
Canadian Society of Civil Engineering Annual Conference ; 2021
Proceedings of the Canadian Society of Civil Engineering Annual Conference 2021 ; Chapter: 17 ; 211-220
2022-05-24
10 pages
Article/Chapter (Book)
Electronic Resource
English
Shear wall energy dissipation anti-shear connector of cross-laminated timber
European Patent Office | 2020
|Reinforced cross-laminated timber-concrete composite floor systems
Elsevier | 2023
|Steel-timber Composite Shear Wall with Layered Steel Plates and Timber Cover Plates
European Patent Office | 2024
|