A platform for research: civil engineering, architecture and urbanism
Concrete Confinement Effect in Circular Concrete Sandwiched Double Steel Tubular Stub-Columns
Concrete sandwiched double steel tubular (CSDST) columns have improved ductility under cyclic loads. Two CSDST columns are investigated in this paper (1) CSDST-CS with Circular outer tube and Square inner tube and (2) CSDST-CC with Circular outer tube and Circular inner tube. The confinement of concrete between the annular spaces of the inner and outer tubes is very important for their behaviour. To the authors’ knowledge, the literature is scarce on a validated concrete confinement model for CSDST. In this paper, the concrete confinement mechanism in CSDST columns is explained based on thick-walled cylinder theory and a semi-analytical equation is developed. Hollowness ratio of the cross-section, width to thickness ratio of the outer steel tube, strength of the outer steel tube and sandwiched concrete strength are identified as the main parameters influencing the confinement effect in CSDST. The proposed equation is extended to CSDST-CS with inner square tube approximated as an equivalent circular tube. This assumption is validated by conducting tests on short column specimens under axial compression. With outer tubes being the same, concrete confinement effect in CSDST-CS, CSDST-CC and concrete filled steel tubular column (CFST) are 18%, 20% and 30%, respectively. This study has demonstrated that the presence of double steel tubes does not improve the concrete confinement in CSDST compared to CFST. Further, this study presents a modification to the design equations of EN 1994-1-2 2005-1-1 (Eurocode 4: Design of composite steel and concrete structures Part 1–1: General rules and rules for buildings. European Committee for Standardization, Brussels, 2004) for CFST columns to CSDST stub columns by incorporating the effect of hollowness.
Concrete Confinement Effect in Circular Concrete Sandwiched Double Steel Tubular Stub-Columns
Concrete sandwiched double steel tubular (CSDST) columns have improved ductility under cyclic loads. Two CSDST columns are investigated in this paper (1) CSDST-CS with Circular outer tube and Square inner tube and (2) CSDST-CC with Circular outer tube and Circular inner tube. The confinement of concrete between the annular spaces of the inner and outer tubes is very important for their behaviour. To the authors’ knowledge, the literature is scarce on a validated concrete confinement model for CSDST. In this paper, the concrete confinement mechanism in CSDST columns is explained based on thick-walled cylinder theory and a semi-analytical equation is developed. Hollowness ratio of the cross-section, width to thickness ratio of the outer steel tube, strength of the outer steel tube and sandwiched concrete strength are identified as the main parameters influencing the confinement effect in CSDST. The proposed equation is extended to CSDST-CS with inner square tube approximated as an equivalent circular tube. This assumption is validated by conducting tests on short column specimens under axial compression. With outer tubes being the same, concrete confinement effect in CSDST-CS, CSDST-CC and concrete filled steel tubular column (CFST) are 18%, 20% and 30%, respectively. This study has demonstrated that the presence of double steel tubes does not improve the concrete confinement in CSDST compared to CFST. Further, this study presents a modification to the design equations of EN 1994-1-2 2005-1-1 (Eurocode 4: Design of composite steel and concrete structures Part 1–1: General rules and rules for buildings. European Committee for Standardization, Brussels, 2004) for CFST columns to CSDST stub columns by incorporating the effect of hollowness.
Concrete Confinement Effect in Circular Concrete Sandwiched Double Steel Tubular Stub-Columns
Int J Steel Struct
Sulthana, U. Mashudha (author) / Jayachandran, S. Arul (author)
International Journal of Steel Structures ; 20 ; 1364-1377
2020-08-01
14 pages
Article (Journal)
Electronic Resource
English
Confinement effect of stiffened and unstiffened concrete-filled stainless steel tubular stub columns
Online Contents | 2009
|Confinement effect of stiffened and unstiffened concrete-filled stainless steel tubular stub columns
Online Contents | 2009
|Concrete filled double circular steel tube (CFDCST) stub columns
Elsevier | 2016
|Concrete filled double circular steel tube (CFDCST) stub columns
Online Contents | 2017
|