A platform for research: civil engineering, architecture and urbanism
Seismic Strength of One-Story Precast Building Dowel Connections
Abstract Typical European precast buildings commonly show dowel beam-to-column connections which consist of vertical steel dowels, embedded in the column and passing through or inserted in holes in the beam. These connections can be characterized by two different failure modes depending on the concrete cover/dowel diameter ratio so that the failure mode involves the yielding of the dowel and the crushing of the concrete around the dowel or the concrete cover splitting in the direction of the load or in the orthogonal direction (side splitting). In this paper, beam-to-column dowel connections are designed according to the Italian seismic building code and the Eurocode 8 general principles, for a set of case-study buildings, considering different geometrical layouts for primary structure and different seismic hazard levels. Different connection configurations are also considered and the connection shear strength is estimated taking into account code and literature formulations, in order to assess their seismic performance.
Seismic Strength of One-Story Precast Building Dowel Connections
Abstract Typical European precast buildings commonly show dowel beam-to-column connections which consist of vertical steel dowels, embedded in the column and passing through or inserted in holes in the beam. These connections can be characterized by two different failure modes depending on the concrete cover/dowel diameter ratio so that the failure mode involves the yielding of the dowel and the crushing of the concrete around the dowel or the concrete cover splitting in the direction of the load or in the orthogonal direction (side splitting). In this paper, beam-to-column dowel connections are designed according to the Italian seismic building code and the Eurocode 8 general principles, for a set of case-study buildings, considering different geometrical layouts for primary structure and different seismic hazard levels. Different connection configurations are also considered and the connection shear strength is estimated taking into account code and literature formulations, in order to assess their seismic performance.
Seismic Strength of One-Story Precast Building Dowel Connections
Cimmino, M. (author) / Magliulo, G. (author) / Manfredi, G. (author)
2019-09-05
14 pages
Article/Chapter (Book)
Electronic Resource
English
Seismic performance of precast reinforced concrete buildings with dowel pin connections
BASE | 2016
|