A platform for research: civil engineering, architecture and urbanism
Local buckling in the stub columns fabricated with HSA800 of high performance steel
Abstract Recently, high-performance steels have been increasingly used for structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using new high-performance steel with the material properties of HSA800 (High-performance Steel having tensile strength of 800 MPa for building structures). The steel stub columns of built-up H-section and square hollow section with various width-to-thickness ratios are experimentally planned to investigate the local buckling behaviors and then to check their current design limits. The nonlinear three-dimensional finite element models are also constructed to verify the experimental results. The present experimental results are seen to closely agree with those from finite element analysis. In addition, the verified finite element models are used for extensive parametric studies to check up the applicability of highstrength steel in current design specification.
Local buckling in the stub columns fabricated with HSA800 of high performance steel
Abstract Recently, high-performance steels have been increasingly used for structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. This paper is a series of basic study for the design specification of structural members using new high-performance steel with the material properties of HSA800 (High-performance Steel having tensile strength of 800 MPa for building structures). The steel stub columns of built-up H-section and square hollow section with various width-to-thickness ratios are experimentally planned to investigate the local buckling behaviors and then to check their current design limits. The nonlinear three-dimensional finite element models are also constructed to verify the experimental results. The present experimental results are seen to closely agree with those from finite element analysis. In addition, the verified finite element models are used for extensive parametric studies to check up the applicability of highstrength steel in current design specification.
Local buckling in the stub columns fabricated with HSA800 of high performance steel
Yoo, Jung-Han (author) / Kim, Joo-Woo (author) / Yang, Jae-Guen (author) / Kang, Joo-Won (author) / Lee, Myung-Jae (author)
International Journal of Steel Structures ; 13 ; 445-458
2013-09-01
14 pages
Article (Journal)
Electronic Resource
English
Post Local Buckling Behavior of H-shaped Steel Stub-Columns
British Library Conference Proceedings | 1995
|Local buckling of 460MPa high strength steel welded section stub columns under axial compression
Online Contents | 2014
|Local buckling behavior of welded π-shaped compression stub columns
British Library Online Contents | 2019
|