A platform for research: civil engineering, architecture and urbanism
Effect of transverse reinforcement on bond strength of reinforcing bars in silica fume concrete
Abstract The objectives of the research program were to investigate the effect of transverse reinforcement on the bond-slip characteristics of tension lap splices in high performance silica fume concrete, to study the validity of the upper limit of 70 MPa imposed by the ACI Building Code 318-95 on the concrete compressive strength for determination of development length, and to evaluate the reliability of the empirical equation of Orangun, Jirsa, and Breen in estimating the bond strength of tension lap splices embedded in high strength concrete and confined with transverse reinforcement. Twelve beam specimens were tested. Each beam specimen included two bars in tension, spliced at the center of the span. The beams were designed in way that bars would fail in bond, splitting the concrete conver in the splice region, before reaching the yield splice in a constant moment region. The variables used were the percentage replacement by weight of cement by silica fume and the amount of confinement over the splice region. Test results indicated that silica fume decreased the bond strength and that specimens containing silica fume but without transverse reinforcement in the splice region had a brittle, sudden and noisy mode of failure. The use of transverse reinforcement in the splice region increased the bond strength and the ductibility of the mode of failure of the beam specimens. Minimum amount of transverse reinforcement was recommended.
Résumé Les objectifs du programme de recherche consistent à examiner l'effet des armatures transversales sur les caractéristiques de glissement des longueurs de recouvrement en tension des armatures d'un BHP (béton de hautes performances) utilisant de la fumée de silice, afin d'étudier la validité de la limite supérieure de 70 MPa imposée par le ACI Building code 318-95 sur la résistance à la compression du béton pour la détermination de la longueur de scellement, et afin d'évaluer la fiabilité de l'équation empirique d'Orangun, Jirsa et Brean dans l'estimation de la force d'adhérence des longueurs de recouvrement en tension, encastrées dans un béton de hautes performances et confinées avec des armatures transversales. Douze spécimens de poutre ont été testées. Chaque spécimen de poutre contenait deux armatures en tension, dont le recouvrement se situe au centre de la portée. Les poutres ont été étudiées de façon à présenter une rupture en adhérence, fissurant l'enrobage du béton dans la région de recouvrement, avant d'atteindre la limite de résistance. Les poutres ont été chargées avec un moment positif, le recouvrement étant situé dans une région de moment constant. Les variables utilisées étaient le pourcentage en poids de ciment remplacé par de la fumée de silice et la zone de confinement dans la région de recouvrement. Les résultats des essais indiquent que la fumée de silice diminue la force d'adhérence, et que les spécimens contenant de la fumée de silice sans armature transversale dans la région de recouvrement présentent une rupture fragile, soudaine et sonore. L'usage des armatures transversales dans la région de recouvrement a augmenté la force d'adhérence et la ductilité du type de rupture des spécimens de poutres. Une quantité minimale d'armatures transversales est conseillée.
Effect of transverse reinforcement on bond strength of reinforcing bars in silica fume concrete
Abstract The objectives of the research program were to investigate the effect of transverse reinforcement on the bond-slip characteristics of tension lap splices in high performance silica fume concrete, to study the validity of the upper limit of 70 MPa imposed by the ACI Building Code 318-95 on the concrete compressive strength for determination of development length, and to evaluate the reliability of the empirical equation of Orangun, Jirsa, and Breen in estimating the bond strength of tension lap splices embedded in high strength concrete and confined with transverse reinforcement. Twelve beam specimens were tested. Each beam specimen included two bars in tension, spliced at the center of the span. The beams were designed in way that bars would fail in bond, splitting the concrete conver in the splice region, before reaching the yield splice in a constant moment region. The variables used were the percentage replacement by weight of cement by silica fume and the amount of confinement over the splice region. Test results indicated that silica fume decreased the bond strength and that specimens containing silica fume but without transverse reinforcement in the splice region had a brittle, sudden and noisy mode of failure. The use of transverse reinforcement in the splice region increased the bond strength and the ductibility of the mode of failure of the beam specimens. Minimum amount of transverse reinforcement was recommended.
Résumé Les objectifs du programme de recherche consistent à examiner l'effet des armatures transversales sur les caractéristiques de glissement des longueurs de recouvrement en tension des armatures d'un BHP (béton de hautes performances) utilisant de la fumée de silice, afin d'étudier la validité de la limite supérieure de 70 MPa imposée par le ACI Building code 318-95 sur la résistance à la compression du béton pour la détermination de la longueur de scellement, et afin d'évaluer la fiabilité de l'équation empirique d'Orangun, Jirsa et Brean dans l'estimation de la force d'adhérence des longueurs de recouvrement en tension, encastrées dans un béton de hautes performances et confinées avec des armatures transversales. Douze spécimens de poutre ont été testées. Chaque spécimen de poutre contenait deux armatures en tension, dont le recouvrement se situe au centre de la portée. Les poutres ont été étudiées de façon à présenter une rupture en adhérence, fissurant l'enrobage du béton dans la région de recouvrement, avant d'atteindre la limite de résistance. Les poutres ont été chargées avec un moment positif, le recouvrement étant situé dans une région de moment constant. Les variables utilisées étaient le pourcentage en poids de ciment remplacé par de la fumée de silice et la zone de confinement dans la région de recouvrement. Les résultats des essais indiquent que la fumée de silice diminue la force d'adhérence, et que les spécimens contenant de la fumée de silice sans armature transversale dans la région de recouvrement présentent une rupture fragile, soudaine et sonore. L'usage des armatures transversales dans la région de recouvrement a augmenté la force d'adhérence et la ductilité du type de rupture des spécimens de poutres. Une quantité minimale d'armatures transversales est conseillée.
Effect of transverse reinforcement on bond strength of reinforcing bars in silica fume concrete
Hamad, B. S. (author) / Machaka, M. F. (author)
Materials and Structures ; 32 ; 468-476
1999-07-01
9 pages
Article (Journal)
Electronic Resource
English
Effect of transverse reinforcement on bond strength of reinforcing bars in silica fume concrete
British Library Online Contents | 1999
|Effect of transverse reinforcement on bond strength of reinforcing bars in silica fume concrete
Online Contents | 1999
|Bond Studies of Reinforcing Bars in Silica Fume Concrete
British Library Conference Proceedings | 1998
|OVERVIEW OF ANCHORAGE PROBLEMS OF REINFORCING BARS IN HIGHPERFORMANCE SILICA FUME CONCRETE
British Library Conference Proceedings | 2000
|