A platform for research: civil engineering, architecture and urbanism
Experimental investigation of beam-to-column connection with SHN490 steel under cyclic loading
Abstract Seismic performance of beam-to-column connections used in the middle-low rise buildings was investigated through the cyclic loading test. Four joint specimens were prepared in accordance with the variables of material and connection type. In two cases of welded connection, the brittle fracture in weld did not occur but cracked at heat-affected zone (HAZ) and/or near weld access hole. In the connections with extended end-plate, punching failure followed by end-plate failure occurred at the flange of column around bolt head. The moment capacities based on failure modes were calculated and compared with the test results. The connections were classified as rigid, semi-rigid, flexible in terms of bending stiffness and strength.
Experimental investigation of beam-to-column connection with SHN490 steel under cyclic loading
Abstract Seismic performance of beam-to-column connections used in the middle-low rise buildings was investigated through the cyclic loading test. Four joint specimens were prepared in accordance with the variables of material and connection type. In two cases of welded connection, the brittle fracture in weld did not occur but cracked at heat-affected zone (HAZ) and/or near weld access hole. In the connections with extended end-plate, punching failure followed by end-plate failure occurred at the flange of column around bolt head. The moment capacities based on failure modes were calculated and compared with the test results. The connections were classified as rigid, semi-rigid, flexible in terms of bending stiffness and strength.
Experimental investigation of beam-to-column connection with SHN490 steel under cyclic loading
Kim, So-Yeong (author) / Shin, Kyung-Jae (author) / Lee, Swoo-Heon (author) / Lee, Hee-Du (author)
International Journal of Steel Structures ; 16 ; 1299-1307
2016-12-01
9 pages
Article (Journal)
Electronic Resource
English
Experimental investigation of beam-to-column connection with SHN490 steel under cyclic loading
Online Contents | 2016
|Comparative Study of Steel Beam Column Connection under Cyclic Loading
British Library Conference Proceedings | 2017
|Experimental investigation of CFT column to steel beam connections under cyclic loading
Online Contents | 2013
|Analysis of steel beam column connection under cyclic loading with reduced web opening type fuses
Springer Verlag | 2024
|