A platform for research: civil engineering, architecture and urbanism
Structural Fire Test Research Programmes for Post-tensioned Concrete
In 1898, in the offices of the Roebling Company at 121 Liberty street in New York City (present day location of the ‘Ground Zero’ World Trade Center memorial), Abraham Himmelwright wrote the original necessary requirements for ideal structural fire testing to be of value. Structural fire tests performed at Himmelwright’s time were based upon an experimental methodology developed by mechanical engineer of the New York Building Department, Gus Henning in 1896 (Himmelwright 1898; Woolson 1902). Inspired to respond to the various ad-hoc structure fire tests of materials, the test series were conducted to develop “actual and relative efficiencies of different floor constructions” under fire (Himmelwright 1898). Henning would later denounce the early fire testing as fraud due to its non-representation of reality (Fig. 3.1).
Structural Fire Test Research Programmes for Post-tensioned Concrete
In 1898, in the offices of the Roebling Company at 121 Liberty street in New York City (present day location of the ‘Ground Zero’ World Trade Center memorial), Abraham Himmelwright wrote the original necessary requirements for ideal structural fire testing to be of value. Structural fire tests performed at Himmelwright’s time were based upon an experimental methodology developed by mechanical engineer of the New York Building Department, Gus Henning in 1896 (Himmelwright 1898; Woolson 1902). Inspired to respond to the various ad-hoc structure fire tests of materials, the test series were conducted to develop “actual and relative efficiencies of different floor constructions” under fire (Himmelwright 1898). Henning would later denounce the early fire testing as fraud due to its non-representation of reality (Fig. 3.1).
Structural Fire Test Research Programmes for Post-tensioned Concrete
SpringerBriefs in Fire
Gales, John (author) / Hartin, Kathleen (author) / Bisby, Luke (author)
Structural Fire Performance of Contemporary Post-tensioned Concrete Construction ; Chapter: 3 ; 17-37
2016-01-01
21 pages
Article/Chapter (Book)
Electronic Resource
English
"Post-Tensioned Concrete Building Fire: Update"
British Library Online Contents | 2000
Post tensioned concrete slabs under fire conditions
British Library Online Contents | 2009
Structural fire performance of post-tensioned concrete slabs with unbonded tendons
BASE | 2014
|Fire tests on bonded post-tensioned concrete slabs
Online Contents | 2009
|