A platform for research: civil engineering, architecture and urbanism
Seismic Response Control of Unsymmetrical RCC Framed Building Using Base Isolation Considering Soil Structure Interaction
Abstract In passive energy dissipation systems used for earthquake resistant structures, base isolation is one of the most powerful systems. For understanding the effect of base isolation system, G + 5 storey models are considered with planner asymmetry. Lead rubber isolator is used for controlling the response of building during earthquake effects and tremors. The paper deals with behavior of fixed base and isolated building in terms of natural time period, top floor acceleration, storey drift, base reaction and energy dissipation. The Non-linear Time history analysis has been performed by using FEM based software SAP2000. The paper also includes the effect of soil structure interaction on both fixed base and isolated base building. It was observed that with use of isolators, time period of structure becomes double as compared with the fixed base model. The soil parameters also plays vital role in performance of isolators.
Seismic Response Control of Unsymmetrical RCC Framed Building Using Base Isolation Considering Soil Structure Interaction
Abstract In passive energy dissipation systems used for earthquake resistant structures, base isolation is one of the most powerful systems. For understanding the effect of base isolation system, G + 5 storey models are considered with planner asymmetry. Lead rubber isolator is used for controlling the response of building during earthquake effects and tremors. The paper deals with behavior of fixed base and isolated building in terms of natural time period, top floor acceleration, storey drift, base reaction and energy dissipation. The Non-linear Time history analysis has been performed by using FEM based software SAP2000. The paper also includes the effect of soil structure interaction on both fixed base and isolated base building. It was observed that with use of isolators, time period of structure becomes double as compared with the fixed base model. The soil parameters also plays vital role in performance of isolators.
Seismic Response Control of Unsymmetrical RCC Framed Building Using Base Isolation Considering Soil Structure Interaction
Jain, Monika (author) / Sanghai, S. S. (author)
2019-06-14
9 pages
Article/Chapter (Book)
Electronic Resource
English
Seismic base isolation for framed structures
British Library Conference Proceedings | 1995
|Study of Seismic Base Isolation of Bridge Considering Soil Structure Interaction
British Library Conference Proceedings | 1995
|DOAJ | 2019
|Seismic response of tall building considering soil-pile-structure interaction
Online Contents | 2002
|Seismic Response Analysis of Soil-Structure Interaction on Base Isolation Structure
Trans Tech Publications | 2013
|