A platform for research: civil engineering, architecture and urbanism
Modelling and Experimental Study of Halbach Array Magnetic Coupler
In order to effectively solve the current problems of magnetic couplers such as large area and complex internal coil, the Halbach array magnetic coupler was proposed. According to the specific characteristics of the hybrid magnetic coupler structure, the mathematical model of air gap magnetic flux density is established by using the combination of electric circuit and electromagnetic field solution. Based on the current superposition, the current is converted to the surface of the copper conductor, and the electromagnetic torque model of the space magnetic field is established by integrating the induced electromotive force along the circumferential direction. In order to verify the correctness of theoretical analysis, the 1:4 prototype was designed and manufactured. Then simulation verification and experiment measurement on its mechanical behaviour are performed. The results show that the maximum error of theoretical value, simulation value and test value is 9.3%. Under the same volume size, the output torque of Halbach array magnetic coupler is increased by 16.1% compared with the ordinary disk magnetic coupler. The research could provide the reference for the design and experimental research of magnetic coupler.
Modelling and Experimental Study of Halbach Array Magnetic Coupler
In order to effectively solve the current problems of magnetic couplers such as large area and complex internal coil, the Halbach array magnetic coupler was proposed. According to the specific characteristics of the hybrid magnetic coupler structure, the mathematical model of air gap magnetic flux density is established by using the combination of electric circuit and electromagnetic field solution. Based on the current superposition, the current is converted to the surface of the copper conductor, and the electromagnetic torque model of the space magnetic field is established by integrating the induced electromotive force along the circumferential direction. In order to verify the correctness of theoretical analysis, the 1:4 prototype was designed and manufactured. Then simulation verification and experiment measurement on its mechanical behaviour are performed. The results show that the maximum error of theoretical value, simulation value and test value is 9.3%. Under the same volume size, the output torque of Halbach array magnetic coupler is increased by 16.1% compared with the ordinary disk magnetic coupler. The research could provide the reference for the design and experimental research of magnetic coupler.
Modelling and Experimental Study of Halbach Array Magnetic Coupler
KSCE J Civ Eng
Li, De-yong (author) / Wang, Shuang (author) / Guo, Yongcun (author) / Ma, Xin (author)
KSCE Journal of Civil Engineering ; 27 ; 261-269
2023-01-01
9 pages
Article (Journal)
Electronic Resource
English
Halbach Array Induced Magnetic Field Alignment in Boron Nitride Nanocomposites
Wiley | 2025
|Halbach Array Induced Magnetic Field Alignment in Boron Nitride Nanocomposites
Wiley | 2025
|Vibration energy harvesting using the Halbach array
British Library Online Contents | 2012
|