Dynamic variation in dew-point temperature of attached air layer of radiant ceiling cooling panels
The present article describes the integration of a data-driven predictive demand response control for residential buildings with heat pump and on-site energy generation. The data driven control approach schedules the heating system of the building. In each day, the next 24 hours heating demand of buildings, including space heating and domestic hot water consumption, are predicted by means of a hybrid wavelet transformation and a dynamic neural network. Linear programming is implemented to define a cost-optimal schedule for the heat pump operation. Moreover, the study discusses the impact of heat demand prediction error on performance of demand response control. In addition, the option of energy trading with the electrical grid is considered in order to evaluate the possibility of increasing the profit for private householders through on-site energy generation. The results highlight that the application of the proposed predictive control could reduce the heating energy cost up to 12% in the cold Finnish climate. Furthermore, on-site energy generation declines the total energy cost and consumption about 43% and 24% respectively. The application of a data-driven control for the demand prediction brings efficiency to demand response control.
Dynamic variation in dew-point temperature of attached air layer of radiant ceiling cooling panels
The present article describes the integration of a data-driven predictive demand response control for residential buildings with heat pump and on-site energy generation. The data driven control approach schedules the heating system of the building. In each day, the next 24 hours heating demand of buildings, including space heating and domestic hot water consumption, are predicted by means of a hybrid wavelet transformation and a dynamic neural network. Linear programming is implemented to define a cost-optimal schedule for the heat pump operation. Moreover, the study discusses the impact of heat demand prediction error on performance of demand response control. In addition, the option of energy trading with the electrical grid is considered in order to evaluate the possibility of increasing the profit for private householders through on-site energy generation. The results highlight that the application of the proposed predictive control could reduce the heating energy cost up to 12% in the cold Finnish climate. Furthermore, on-site energy generation declines the total energy cost and consumption about 43% and 24% respectively. The application of a data-driven control for the demand prediction brings efficiency to demand response control.
Dynamic variation in dew-point temperature of attached air layer of radiant ceiling cooling panels
Build. Simul.
Jin, Wufeng (author) / Ma, Jingda (author) / Bi, Chen (author) / Wang, Zhiqiang (author) / Soo, Choi Bong (author) / Gao, Pan (author)
Building Simulation ; 13 ; 1281-1290
2020-12-01
10 pages
Article (Journal)
Electronic Resource
English
Applied Performance of Radiant Ceiling Panels for Cooling
British Library Conference Proceedings | 2006
|Applied Performance of Radiant Ceiling Panels for Cooling
British Library Online Contents | 2006
|Computer simulation of ceiling radiant heating and cooling panels and comfort evaluation
British Library Conference Proceedings | 2000
|Room-side and Plenum-side Cooling Prediction of Suspended Radiant Ceiling Panels
BASE | 2022
|