A platform for research: civil engineering, architecture and urbanism
Flow pattern and thermal comfort in office environment with active chilled beams
In modern offices, the heat load per floor area has increased. With high cooling loads, the possibility of draft problems increases. The purpose of this article was to study the flow patterns and draft risk in an office environment where cooling and air distribution is implemented with active chilled beams. The study is based on experiments in a laboratory mock-up room in three load conditions: summer, winter, and midseason (spring/autumn). Thermal plumes from heat sources and warm or cold windows had a notable effect on the flow pattern and velocity distribution in the occupied zone. Areas with increased draft risk were found in locations where the supply jet turns down to the occupied zone. Draft risk can also be high at the floor level as a result of a circulating flow pattern in the room. This article concentrates on measurement and modeling results in a single-person office room. Comparisons are made with corresponding results in an open-plan office.
Flow pattern and thermal comfort in office environment with active chilled beams
In modern offices, the heat load per floor area has increased. With high cooling loads, the possibility of draft problems increases. The purpose of this article was to study the flow patterns and draft risk in an office environment where cooling and air distribution is implemented with active chilled beams. The study is based on experiments in a laboratory mock-up room in three load conditions: summer, winter, and midseason (spring/autumn). Thermal plumes from heat sources and warm or cold windows had a notable effect on the flow pattern and velocity distribution in the occupied zone. Areas with increased draft risk were found in locations where the supply jet turns down to the occupied zone. Draft risk can also be high at the floor level as a result of a circulating flow pattern in the room. This article concentrates on measurement and modeling results in a single-person office room. Comparisons are made with corresponding results in an open-plan office.
Flow pattern and thermal comfort in office environment with active chilled beams
Koskela, Hannu (author) / Häggblom, Henna (author) / Kosonen, Risto (author) / Ruponen, Mika (author)
HVAC&R Research ; 18 ; 723-736
2012-08-01
14 pages
Article (Journal)
Electronic Resource
Unknown
Air distribution in office environment with asymmetric workstation layout using chilled beams
British Library Online Contents | 2010
|Air distribution in office environment with asymmetric workstation layout using chilled beams
Online Contents | 2010
|Heat source effects on thermal comfort for active chilled beam systems
British Library Online Contents | 2018
|IN THE COMFORT ZONE - Chilled-beam units in 1970s office refurb
Online Contents | 2009