A platform for research: civil engineering, architecture and urbanism
Tracer Gas Measurement of Airflow Rates in Spaces with Several Air-Handling Units, Recirculation, or Large Time Constants
Methods to measure airflow rates using tracer gas in single air-handling units are well known. In some buildings, however, in particular in Singapore, rooms are often ventilated with two or more units and present large recirculation rates. Large recirculation ratios homogenize the concentrations, so concentrations in supply and extract ducts are close to each other. In addition, these spaces often present a large time constant, so much time is needed to reach steady state. The purpose of this paper is to document an adapted methodology to measure not only the airflow rates provided by each unit but also the inter-unit airflow rates and the global ventilation efficiency, The method is illustrated with an example of measurement in an actual building. It is shown that the most accurate method is not the same for small and large recirculation ratios.
Tracer Gas Measurement of Airflow Rates in Spaces with Several Air-Handling Units, Recirculation, or Large Time Constants
Methods to measure airflow rates using tracer gas in single air-handling units are well known. In some buildings, however, in particular in Singapore, rooms are often ventilated with two or more units and present large recirculation rates. Large recirculation ratios homogenize the concentrations, so concentrations in supply and extract ducts are close to each other. In addition, these spaces often present a large time constant, so much time is needed to reach steady state. The purpose of this paper is to document an adapted methodology to measure not only the airflow rates provided by each unit but also the inter-unit airflow rates and the global ventilation efficiency, The method is illustrated with an example of measurement in an actual building. It is shown that the most accurate method is not the same for small and large recirculation ratios.
Tracer Gas Measurement of Airflow Rates in Spaces with Several Air-Handling Units, Recirculation, or Large Time Constants
Roulet, C.-A. (author) / Zuraimi, M. S. (author) / Sekhar, S. C. (author) / Tham, K. W. (author)
HVAC&R Research ; 12 ; 477-496
2006-07-01
20 pages
Article (Journal)
Electronic Resource
Unknown
Estimating airflow rates in air-handling units from actuator control signals
British Library Online Contents | 2006
|Estimating airflow rates in air-handling units from actuator control signals
Online Contents | 2006
|Airflow in ducts: Measurement by perfluorocarbon (PFT) tracer
British Library Online Contents | 1994
|Variations in Interzonal Airflow Rates in a Detached House Using Tracer Gas Techniques
British Library Online Contents | 1993
|