Bench-scale evaluation of ferrous iron oxidation kinetics in drinking water: Effect of corrosion control and dissolved organic matter
Corrosion control strategies are important for many utilities in maintaining water quality from the water treatment plant to the customers’ tap. In drinking water with low alkalinity, water quality can become significantly degraded in iron-based pipes if water utilities are not diligent in maintaining proper corrosion control. This article reports on experiments conducted in bicarbonate buffered (5 mg-C/L) synthetic water to determine the effects of corrosion control (pH and phosphate) and dissolved organic matter (DOM) on the rate constants of the Fe(II) oxidation process. A factorial design approach elucidated that pH (P = 0.007, contribution: 42.5%) and phosphate (P = 0.025, contribution: 22.7%) were the statistically significant factors in the Fe(II) oxidation process at a 95% confidence level. The comprehensive study revealed a significant dependency relationship between the Fe(II) oxidation rate constants (k) and phosphate-to- Fe(II) mole ratio. At pH 6.5, the optimum mole ratio was found to be 0.3 to reduce the k values. Conversely, the k values were observed to increase for the phosphate-to- Fe(II) mole ratio >1. The factorial design approach revealed that chlorine and DOM for the designated dosages did not cause a statistically significant (α=0.05, P>0.05) change in rate constants. However, an increment of the chlorine to ferrous iron mole ratio by a factor of ∼2.5 resulted in an increase k values by a factor of ∼10. This study conclusively demonstrated that the lowest Fe(II) oxidation rate constant was obtained under low pH conditions (pH ≤ 6.5), with chlorine doses less than 2.2 mg/L and with a phosphate-to-Fe(II) mole ratio≈0.3 in the iron water systems.
Bench-scale evaluation of ferrous iron oxidation kinetics in drinking water: Effect of corrosion control and dissolved organic matter
Corrosion control strategies are important for many utilities in maintaining water quality from the water treatment plant to the customers’ tap. In drinking water with low alkalinity, water quality can become significantly degraded in iron-based pipes if water utilities are not diligent in maintaining proper corrosion control. This article reports on experiments conducted in bicarbonate buffered (5 mg-C/L) synthetic water to determine the effects of corrosion control (pH and phosphate) and dissolved organic matter (DOM) on the rate constants of the Fe(II) oxidation process. A factorial design approach elucidated that pH (P = 0.007, contribution: 42.5%) and phosphate (P = 0.025, contribution: 22.7%) were the statistically significant factors in the Fe(II) oxidation process at a 95% confidence level. The comprehensive study revealed a significant dependency relationship between the Fe(II) oxidation rate constants (k) and phosphate-to- Fe(II) mole ratio. At pH 6.5, the optimum mole ratio was found to be 0.3 to reduce the k values. Conversely, the k values were observed to increase for the phosphate-to- Fe(II) mole ratio >1. The factorial design approach revealed that chlorine and DOM for the designated dosages did not cause a statistically significant (α=0.05, P>0.05) change in rate constants. However, an increment of the chlorine to ferrous iron mole ratio by a factor of ∼2.5 resulted in an increase k values by a factor of ∼10. This study conclusively demonstrated that the lowest Fe(II) oxidation rate constant was obtained under low pH conditions (pH ≤ 6.5), with chlorine doses less than 2.2 mg/L and with a phosphate-to-Fe(II) mole ratio≈0.3 in the iron water systems.
Bench-scale evaluation of ferrous iron oxidation kinetics in drinking water: Effect of corrosion control and dissolved organic matter
Rahman, M. Safiur (author) / Gagnon, Graham A. (author)
2014-01-02
9 pages
Article (Journal)
Electronic Resource
English
Dissolved Organic Matter Fractions and Their Removal in Full-Scale Drinking Water Treatment Process
DOAJ | 2023
|British Library Conference Proceedings | 2004
|Hybrid Process for Dissolved Organic Matter Removal in Drinking Water Resources
British Library Conference Proceedings | 2006
|Effects of Dissolved Organic Matter on Corrosion of Cast Iron Pipe for Reclaimed Water
British Library Online Contents | 2018
|