Energy balances are performed on selected converging and diverging flow tees and laterals to calculate the net energy loss in order to quantify the total energy loss expected for a particular application. The goal is to identify those divided flow fittings that exhibit the minimum total energy loss so that the least fan power consumption will be required when such fittings are installed in an air duct system. Loss coefficient correlations previously published in literature are employed in the analysis. The total energy dissipation is expressed in terms of branch and main loss coefficients. It is shown that the total energy loss is positive within the limited accuracy of the published correlations for loss coefficient data. A physically realistic explanation is provided for previously reported negative main and branch loss coefficients. A range of branch-to-common flow rate ratios is identified for converging flow straight-body flat oval 45° laterals in order to minimize energy loss.
Energy balance analysis of HVAC divided flow fittings
Energy balances are performed on selected converging and diverging flow tees and laterals to calculate the net energy loss in order to quantify the total energy loss expected for a particular application. The goal is to identify those divided flow fittings that exhibit the minimum total energy loss so that the least fan power consumption will be required when such fittings are installed in an air duct system. Loss coefficient correlations previously published in literature are employed in the analysis. The total energy dissipation is expressed in terms of branch and main loss coefficients. It is shown that the total energy loss is positive within the limited accuracy of the published correlations for loss coefficient data. A physically realistic explanation is provided for previously reported negative main and branch loss coefficients. A range of branch-to-common flow rate ratios is identified for converging flow straight-body flat oval 45° laterals in order to minimize energy loss.
Energy balance analysis of HVAC divided flow fittings
Kulkarni, Devendra (author) / Idem, Stephen (author)
Science and Technology for the Built Environment ; 23 ; 218-225
2017-01-02
8 pages
Article (Journal)
Electronic Resource
English
Loss Coefficient Measurements in Divided-Flow Flat Oval Fittings
British Library Online Contents | 1996
|Loss Coefficient Measurements in Divided-Flow Flat Oval Fittings
British Library Conference Proceedings | 1996
|New ASHRAE Local Loss Coefficients for HVAC Fittings (RP-551)
British Library Conference Proceedings | 1993
|New ASHRAE Local Loss Coefficients for HVAC Fittings (RP-551)
British Library Online Contents | 1993
|Effect on pressure loss of separation and orientation of closely coupled HVAC duct fittings
British Library Online Contents | 2000
|