Experimental validation of the multiple-zone system ventilation efficiency equation of ANSI/ASHRAE Standard 62.1 (1276-RP)
This article describes an experiment that was carried out on an existing building to test the validity of the system ventilation efficiency equation for multiple-zone recirculating systems of ANSI/ASHRAE Standard 62.1. The system ventilation efficiency equation (SVEE) can be applied to buildings that use a recirculating air distribution system. It accounts for the fact that the return air carries some “unused” outdoor air, so that the amount of new outdoor air introduced at the air handler can be reduced. The SVEE is based on a mass balance, but infiltration and interzonal mixing are not included in the formulation. Since infiltration is unpredictable, it can't be relied upon to ventilate a space, so the validation focuses on interzonal mixing. The experiment uses tracer gas techniques to study the air distribution in an existing office building, with four zones being treated as nominal critical zones. The tests are conducted with constant flow rates under a range of conditions. The SVEE is found to be a very good predictor of ventilation distribution in the building.
Experimental validation of the multiple-zone system ventilation efficiency equation of ANSI/ASHRAE Standard 62.1 (1276-RP)
This article describes an experiment that was carried out on an existing building to test the validity of the system ventilation efficiency equation for multiple-zone recirculating systems of ANSI/ASHRAE Standard 62.1. The system ventilation efficiency equation (SVEE) can be applied to buildings that use a recirculating air distribution system. It accounts for the fact that the return air carries some “unused” outdoor air, so that the amount of new outdoor air introduced at the air handler can be reduced. The SVEE is based on a mass balance, but infiltration and interzonal mixing are not included in the formulation. Since infiltration is unpredictable, it can't be relied upon to ventilate a space, so the validation focuses on interzonal mixing. The experiment uses tracer gas techniques to study the air distribution in an existing office building, with four zones being treated as nominal critical zones. The tests are conducted with constant flow rates under a range of conditions. The SVEE is found to be a very good predictor of ventilation distribution in the building.
Experimental validation of the multiple-zone system ventilation efficiency equation of ANSI/ASHRAE Standard 62.1 (1276-RP)
Yuill, David P. (author) / Yuill, Grenville K. (author) / Coward, Andrew H. (author)
HVAC&R Research ; 18 ; 339-348
2012-06-01
10 pages
Article (Journal)
Electronic Resource
Unknown
New Requirements of ASHRAE Standard 62.1-2010
British Library Online Contents | 2010
|QUIT BLAMING ASHRAE STANDARD 62.1 FOR 1000 PPM CO2
TIBKAT | 2021
|Optimizing Supply Air Temperature with ASHRAE 62.1
British Library Online Contents | 2010
|Codes and Standards - The 2005 NEC; Managing Moisture with ASHRAE 62.1
Online Contents | 2005