A platform for research: civil engineering, architecture and urbanism
Laboratory Characterization of Modified Tapered Element Oscillating Microbalance Samplers
Laboratory tests with generated aerosols were conducted to test the efficacy of two recent design modifications to the well-established tapered element oscillating microbalance (TEOM) continuous particulate matter (PM) mass monitor. The two systems tested were the sample equilibration system-equipped TEOM monitor operating at 30 °C, which uses a Nafion dryer as part of the sample inlet, and the differential TEOM monitor, which adds a switched electrostatic precipitator and uses a self-referencing algorithm to determine “true PM mass.” Test aerosols included ammonium sulfate, ammonium nitrate, sodium chloride, copper (II) sulfate, and mixed aerosols. Aerosols were generated with an atomizer or a vibrating orifice generator and were equilibrated in a 450-L slow flow chamber before being sampled. Relative humidity in the chamber was varied between 10 and 90%, and step changes in humidity were executed while generating aerosol to test the response of the instruments. The sample equilibration system-equipped TEOM monitor does reduce, but not totally eliminate, the sensitivity of the TEOM mass monitor to changes in humidity. The differential TEOM monitor gives every indication of being a very robust technique for the continuous real-time measurement of ambient aerosol mass, even in the presence of semi-volatile particles and condensable gases.
Laboratory Characterization of Modified Tapered Element Oscillating Microbalance Samplers
Laboratory tests with generated aerosols were conducted to test the efficacy of two recent design modifications to the well-established tapered element oscillating microbalance (TEOM) continuous particulate matter (PM) mass monitor. The two systems tested were the sample equilibration system-equipped TEOM monitor operating at 30 °C, which uses a Nafion dryer as part of the sample inlet, and the differential TEOM monitor, which adds a switched electrostatic precipitator and uses a self-referencing algorithm to determine “true PM mass.” Test aerosols included ammonium sulfate, ammonium nitrate, sodium chloride, copper (II) sulfate, and mixed aerosols. Aerosols were generated with an atomizer or a vibrating orifice generator and were equilibrated in a 450-L slow flow chamber before being sampled. Relative humidity in the chamber was varied between 10 and 90%, and step changes in humidity were executed while generating aerosol to test the response of the instruments. The sample equilibration system-equipped TEOM monitor does reduce, but not totally eliminate, the sensitivity of the TEOM mass monitor to changes in humidity. The differential TEOM monitor gives every indication of being a very robust technique for the continuous real-time measurement of ambient aerosol mass, even in the presence of semi-volatile particles and condensable gases.
Laboratory Characterization of Modified Tapered Element Oscillating Microbalance Samplers
Schwab, James J. (author) / Hogrefe, Olga (author) / Demerjian, Kenneth L. (author) / Ambs, Jeffrey L. (author)
Journal of the Air & Waste Management Association ; 54 ; 1254-1263
2004-10-01
10 pages
Article (Journal)
Electronic Resource
Unknown
Taylor & Francis Verlag | 2002
|Taylor & Francis Verlag | 2012
|Taylor & Francis Verlag | 2014
|Taylor & Francis Verlag | 2003
|