A platform for research: civil engineering, architecture and urbanism
Seismic Vulnerability Assessment of Hybrid Steel-Timber Structure: Steel Moment-Resisting Frames with CLT Infill
In this article, seismic vulnerability assessment is carried-out on a novel hybrid structure (steel moment resisting frame (SMRF) and cross laminated timber (CLT) infill panels). For the seismicity of Vancouver, Canada, a three-bay, 3-, 6-, and 9-story height SMRFs are designed for two ductility levels (ductile and limited ductility). To study the seismic vulnerability CLT infilled building, parametric analysis was performed by varying infill configuration (bare frame, one-bay infilled, two-bay infilled, and fully infilled). The structure is modeled in OpenSees and nonlinear dynamic analysis is performed. Peak inter-story drift demand and corresponding FEMA performance limits (capacity) values are used to compute the corresponding fragility curves. From the analyses, it can be seen that as more bays are infilled, the fundamental period and seismic vulnerability is reduced significantly. The results highlight that, within the performance-based earthquake engineering, different objectives can be met with varying the CLT configuration.
Seismic Vulnerability Assessment of Hybrid Steel-Timber Structure: Steel Moment-Resisting Frames with CLT Infill
In this article, seismic vulnerability assessment is carried-out on a novel hybrid structure (steel moment resisting frame (SMRF) and cross laminated timber (CLT) infill panels). For the seismicity of Vancouver, Canada, a three-bay, 3-, 6-, and 9-story height SMRFs are designed for two ductility levels (ductile and limited ductility). To study the seismic vulnerability CLT infilled building, parametric analysis was performed by varying infill configuration (bare frame, one-bay infilled, two-bay infilled, and fully infilled). The structure is modeled in OpenSees and nonlinear dynamic analysis is performed. Peak inter-story drift demand and corresponding FEMA performance limits (capacity) values are used to compute the corresponding fragility curves. From the analyses, it can be seen that as more bays are infilled, the fundamental period and seismic vulnerability is reduced significantly. The results highlight that, within the performance-based earthquake engineering, different objectives can be met with varying the CLT configuration.
Seismic Vulnerability Assessment of Hybrid Steel-Timber Structure: Steel Moment-Resisting Frames with CLT Infill
Tesfamariam, S. (author) / Stiemer, S. F. (author) / Dickof, C. (author) / Bezabeh, M. A. (author)
Journal of Earthquake Engineering ; 18 ; 929-944
2014-08-18
16 pages
Article (Journal)
Electronic Resource
English
Clt infill panels in steel moment resisting frames as a hybrid seismic force resisting system
BASE | 2013
|Clt infill panels in steel moment resisting frames as a hybrid seismic force resisting system
BASE | 2013
|