Experimental comparison of R404A and R452A in refrigeration systems
In this study, R404A and R452A refrigerants used in refrigeration systems were compared experimentally. The energy performance of the system was investigated for widely used evaporation temperatures (−5, 0, +5 °C) and condenser temperatures (25, 35, 45 °C). It was seen that the coefficient of performance (COP) was higher but the power consumption of the system was lower when using R452A as a substitute for R404A. When R452A was used, the COP was improved by about 3% to 8% compared to R404A. Furthermore, the cooling capacity decreased by about 2% for condenser temperatures of 25 and 35 °C, while it increased at a condenser temperature of 45 °C. The power consumption of the system was also reduced by nearly 5%. The mass flow rate of the refrigerant was lower when the system was operated with R452A. In the middle term, R452A could be a suitable alternative refrigerant for commercial refrigeration applications due to its low global warming potential (GWP) value and better energy performance compared to R404A.
Experimental comparison of R404A and R452A in refrigeration systems
In this study, R404A and R452A refrigerants used in refrigeration systems were compared experimentally. The energy performance of the system was investigated for widely used evaporation temperatures (−5, 0, +5 °C) and condenser temperatures (25, 35, 45 °C). It was seen that the coefficient of performance (COP) was higher but the power consumption of the system was lower when using R452A as a substitute for R404A. When R452A was used, the COP was improved by about 3% to 8% compared to R404A. Furthermore, the cooling capacity decreased by about 2% for condenser temperatures of 25 and 35 °C, while it increased at a condenser temperature of 45 °C. The power consumption of the system was also reduced by nearly 5%. The mass flow rate of the refrigerant was lower when the system was operated with R452A. In the middle term, R452A could be a suitable alternative refrigerant for commercial refrigeration applications due to its low global warming potential (GWP) value and better energy performance compared to R404A.
Experimental comparison of R404A and R452A in refrigeration systems
Devecİoğlu, Atİlla G. (author) / Oruç, Vedat (author)
Science and Technology for the Built Environment ; 27 ; 61-69
2020-08-07
9 pages
Article (Journal)
Electronic Resource
Unknown
Comparative energy and exergy analysis of R744, R404A and R290 refrigeration cycles
Oxford University Press | 2009
|Taylor & Francis Verlag | 2016
|Halbhermetischer Hubkolbenverdichter mit Propan im Vergleich zu R22 und R404A
British Library Online Contents | 1996
|