A platform for research: civil engineering, architecture and urbanism
Development and Evaluation of a Continuous Coarse (PM10–PM25) Particle Monitor
In this paper, we describe the development and laboratory and field evaluation of a continuous coarse (2.5-10 um) particle mass (PM) monitor that can provide reliable measurements of the coarse mass (CM) concentrations in time intervals as short as 5-10 min. The operating principle of the monitor is based on enriching CM concentrations by a factor of ~25 by means of a 2.5-um cut point round nozzle virtual impactor while maintaining fine mass (FM)—that is, the mass of PM2 5 at ambient concentrations. The aerosol mixture is subsequently drawn through a standard tapered element oscillating microbalance (TEOM), the response of which is dominated by the contributions of the CM, due to concentration enrichment. Findings from the field study ascertain that a TEOM coupled with a PM10 inlet followed by a 2.5-um cut point round nozzle virtual impactor can be used successfully for continuous CM concentration measurements. The average concentration-enriched CM concentrations measured by the TEOM were 26-27 times higher than those measured by the time-integrated PM10 samplers [the micro-orifice uniform deposit
Development and Evaluation of a Continuous Coarse (PM10–PM25) Particle Monitor
In this paper, we describe the development and laboratory and field evaluation of a continuous coarse (2.5-10 um) particle mass (PM) monitor that can provide reliable measurements of the coarse mass (CM) concentrations in time intervals as short as 5-10 min. The operating principle of the monitor is based on enriching CM concentrations by a factor of ~25 by means of a 2.5-um cut point round nozzle virtual impactor while maintaining fine mass (FM)—that is, the mass of PM2 5 at ambient concentrations. The aerosol mixture is subsequently drawn through a standard tapered element oscillating microbalance (TEOM), the response of which is dominated by the contributions of the CM, due to concentration enrichment. Findings from the field study ascertain that a TEOM coupled with a PM10 inlet followed by a 2.5-um cut point round nozzle virtual impactor can be used successfully for continuous CM concentration measurements. The average concentration-enriched CM concentrations measured by the TEOM were 26-27 times higher than those measured by the time-integrated PM10 samplers [the micro-orifice uniform deposit
Development and Evaluation of a Continuous Coarse (PM10–PM25) Particle Monitor
Misra, Chandan (author) / Geller, Michael D. (author) / Shah, Pranav (author) / Sioutas, Constantinos (author) / Solomon, Paul A. (author)
Journal of the Air & Waste Management Association ; 51 ; 1309-1317
2001-09-01
9 pages
Article (Journal)
Electronic Resource
Unknown
Taylor & Francis Verlag | 2000
|Use of the Aerodynamic Particle Sizer to Measure Ambient PM10–2.5: The Coarse Fraction of PM10
Taylor & Francis Verlag | 2006
|Taylor & Francis Verlag | 1999
|Marginal PM25: Nonlinear Aerosol Mass Response to Sulfate Reductions in the Eastern United States
Taylor & Francis Verlag | 1999
|