A near-optimal control algorithm for central cooling plants with electric and/or gas-driven chillers
This paper presents a near-optimal control algorithm for minimizing energy costs in hybrid cooling plants in response to cooling loads. The approach is based upon an approximate solution to the partial differential equations involved in minimizing the cost of energy consumed by the plant with respect to two control variables: cooling tower airflow and condenser water flow. The parameters of the algorithm can be determined with design information of the chillers and cooling towers, along with some measurements of total condenser water flow and pump power consumption. In addition to reducing plant operating costs, the algorithm simplifies tower control and is more stable compared with conventional tower control strategies such as constant condenser water supply temperature or constant approach to wet-bulb. A large-scale cooling plant model was utilized to evaluate the performance of the approach compared with optimal control and two heuristic control strategies over six months. The difference between the energy costs associated with the near-optimal control approach and optimal control was 1.7%. Comparison with the heuristic control strategies shows that significant energy savings can be achieved with the proposed algorithm.
A near-optimal control algorithm for central cooling plants with electric and/or gas-driven chillers
This paper presents a near-optimal control algorithm for minimizing energy costs in hybrid cooling plants in response to cooling loads. The approach is based upon an approximate solution to the partial differential equations involved in minimizing the cost of energy consumed by the plant with respect to two control variables: cooling tower airflow and condenser water flow. The parameters of the algorithm can be determined with design information of the chillers and cooling towers, along with some measurements of total condenser water flow and pump power consumption. In addition to reducing plant operating costs, the algorithm simplifies tower control and is more stable compared with conventional tower control strategies such as constant condenser water supply temperature or constant approach to wet-bulb. A large-scale cooling plant model was utilized to evaluate the performance of the approach compared with optimal control and two heuristic control strategies over six months. The difference between the energy costs associated with the near-optimal control approach and optimal control was 1.7%. Comparison with the heuristic control strategies shows that significant energy savings can be achieved with the proposed algorithm.
A near-optimal control algorithm for central cooling plants with electric and/or gas-driven chillers
Jaramillo, Rita C. (author) / Braun, James E. (author) / Horton, W. Travis (author)
Science and Technology for the Built Environment ; 26 ; 1132-1150
2020-09-13
19 pages
Article (Journal)
Electronic Resource
English
Taylor & Francis Verlag | 2007
|British Library Online Contents | 1993
OPTIMAL CONTROL FOR CENTRAL COOLING PLANTS
British Library Conference Proceedings | 1999
|Natural-Gas Engine-Driven Chillers
British Library Online Contents | 2000
|Advanced Sorption Chillers for Gas Cooling
British Library Conference Proceedings | 1996
|