A platform for research: civil engineering, architecture and urbanism
Determination of Levoglucosan in Atmospheric Fine Particulate Matter
A microanalytical method suitable for the quantitative determination of the sugar anhydride levoglucosan in low-volume samples of atmospheric fine particulate matter (PM) has been developed and validated. The method incorporates two sugar anhydrides as quality control standards. The recovery standard sedoheptulosan (2,7-anhydro-β-D-altro-heptulopyranose) in 20 μL solvent is added onto samples of the atmospheric fine PM and aged for 1 hr before ultrasonic extraction with ethylacetate/ triethylamine. The extract is reduced in volume, an internal standard is added (1,5-anhydro-D-mannitol), and a portion of the extract is derivatized with 10% by volume N-trimethylsilylimidazole. The derivatized extract is analyzed by gas chromatography/mass spectrometry (GC/MS). The recovery of levoglucosan using this procedure was 69 ± 6% from five filters amended with 2 μg levoglu-cosan, and the reproducibility of the assay is 9%. The limit of detection is ∼0.1 μg/mL, which is equivalent to ∼3.5 ng/m3 for a 10 L/min sampler or ∼8.7 ng/m3 for a 4 L/min personal sampler (assuming 24-hr integrated samples). We demonstrated that levoglucosan concentrations in collocated samples (expressed as ng/m3) were identical irrespective of whether samples were collected by PM with aerodynamic diameter ≤2.5 μm or PM with aerodynamic diameter ≤10 μm impactors. It was also demonstrated that X-ray fluorescence analysis of samples of atmospheric PM, before levoglucosan determinations, did not alter the levels of levoglucosan.
Determination of Levoglucosan in Atmospheric Fine Particulate Matter
A microanalytical method suitable for the quantitative determination of the sugar anhydride levoglucosan in low-volume samples of atmospheric fine particulate matter (PM) has been developed and validated. The method incorporates two sugar anhydrides as quality control standards. The recovery standard sedoheptulosan (2,7-anhydro-β-D-altro-heptulopyranose) in 20 μL solvent is added onto samples of the atmospheric fine PM and aged for 1 hr before ultrasonic extraction with ethylacetate/ triethylamine. The extract is reduced in volume, an internal standard is added (1,5-anhydro-D-mannitol), and a portion of the extract is derivatized with 10% by volume N-trimethylsilylimidazole. The derivatized extract is analyzed by gas chromatography/mass spectrometry (GC/MS). The recovery of levoglucosan using this procedure was 69 ± 6% from five filters amended with 2 μg levoglu-cosan, and the reproducibility of the assay is 9%. The limit of detection is ∼0.1 μg/mL, which is equivalent to ∼3.5 ng/m3 for a 10 L/min sampler or ∼8.7 ng/m3 for a 4 L/min personal sampler (assuming 24-hr integrated samples). We demonstrated that levoglucosan concentrations in collocated samples (expressed as ng/m3) were identical irrespective of whether samples were collected by PM with aerodynamic diameter ≤2.5 μm or PM with aerodynamic diameter ≤10 μm impactors. It was also demonstrated that X-ray fluorescence analysis of samples of atmospheric PM, before levoglucosan determinations, did not alter the levels of levoglucosan.
Determination of Levoglucosan in Atmospheric Fine Particulate Matter
Simpson, Christopher D. (author) / Dills, Russell L. (author) / Katz, Bethany S. (author) / Kalman, David A. (author)
Journal of the Air & Waste Management Association ; 54 ; 689-694
2004-06-01
6 pages
Article (Journal)
Electronic Resource
Unknown
Characterization and seasonal variations of levoglucosan in fine particulate matter in Xi’an, China
Taylor & Francis Verlag | 2014
|Levoglucosan as an atmospheric tracer for woodsmoke
Elsevier | 2006
|