A platform for research: civil engineering, architecture and urbanism
Envelope thermal design for energy savings in mosques in hot-humid climate
Mosques, places of worship for Muslims, are used for five intermittent prayer periods a day with a duration of between 45 and 60 min each. Their unique function and pattern of operation result in unique energy consumption and demand. Although mosques can be characterized as high-occupancy buildings, the thermal design of the exterior envelope can play a major role in their thermal and energy performance particularly in hot-humid climates. The objective of this study is to investigate energy performance and potential energy savings associated with influencing envelope design parameters under hot-humid climatic conditions. The results revealed that envelope parameters such as wall and roof thermal resistance, and air leakage rate are major determinants of mosque energy performance and subsequently, considerable savings can be achieved when properly considered. Recommendations for envelope thermal design are presented to provide architects, engineers, planners, community developers and mosque operators with necessary guidelines for improving mosque energy performance.
Envelope thermal design for energy savings in mosques in hot-humid climate
Mosques, places of worship for Muslims, are used for five intermittent prayer periods a day with a duration of between 45 and 60 min each. Their unique function and pattern of operation result in unique energy consumption and demand. Although mosques can be characterized as high-occupancy buildings, the thermal design of the exterior envelope can play a major role in their thermal and energy performance particularly in hot-humid climates. The objective of this study is to investigate energy performance and potential energy savings associated with influencing envelope design parameters under hot-humid climatic conditions. The results revealed that envelope parameters such as wall and roof thermal resistance, and air leakage rate are major determinants of mosque energy performance and subsequently, considerable savings can be achieved when properly considered. Recommendations for envelope thermal design are presented to provide architects, engineers, planners, community developers and mosque operators with necessary guidelines for improving mosque energy performance.
Envelope thermal design for energy savings in mosques in hot-humid climate
Budaiwi, I. M. (author)
Journal of Building Performance Simulation ; 4 ; 49-61
2011-03-01
13 pages
Article (Journal)
Electronic Resource
English
Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates
Online Contents | 2009
|Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates
Online Contents | 2009
|